Ford OBD1 Systems
ADDITIONAL TESTS FOR EEC-IV SYSTEMS - WIGGLE TEST
104 3160g
2.
Connect the Scan Tool cable (with the
Ford Connector Cable Adaptor attached)
to the Scan Tool, then connect the
adaptor to the vehicle's DLC. Press the
POWER/LINK
button to turn the
Scan Tool ON, then press the
ENTER
button to continue.
The Ford Menu displays.
Use the
and
buttons, as
necessary, to make menu
selections.
3.
From the Ford Menu, highlight
Wiggle
Test
, then press the
ENTER
button.
4.
The message “Warm up engine to
operating temperature” displays. Start
and warm-up engine to normal
operating temperature. Press the
ENTER
button to continue.
5.
When prompted, turn ignition key OFF
and wait for the on screen prompt. If you
wish to exit the KOEO test at this time,
press the
SYSTEM MENU
button.
6.
Select the desired Wiggle Test from the
menu displayed.
To perform the KOEO Wiggle Test:
- Highlight
KOEO Wiggle Test
.
- Turn ignition ON. DO NOT
START THE ENGINE.
- Press the
ENTER
button to
continue.
To perform the KOER Wiggle Test:
- Highlight
KOER Wiggle Test
.
- Turn the ignition ON and start the
engine.
- Press the
ENTER
button to
continue.
7.
A "One moment please test is in
progress" message shows temporarily
on the Scan Tool’s LCD display.