© 2016 InnoMedia, Inc. All rights reserved.
Page 51
InnoMedia MTA8328-1 Administrative Guide
Device Type (0-
254)
This is the device type configured on the
EMS Server, so that a user of the EMS server
will see the device by name (such as 8328-1)
in the device list. The type is also important
for what options/features will be seen when
a device is queried on the EMS.
EMS Server
The IP or FQDN address of the EMS Server
and port. Default is to use port 5200 for
connection to the server.
Password
The password for EMS Server.
Local EMS Port
The port number used at MTA device in
order to connect to EMS server.
Region ID
Region the device is assigned to. This is a
number value that has to be entered, so a
good example of region configuration might
be based on Area Codes. Another example
might be time zones. When the EMS Server
is set up, careful consideration should be
given to how the regions are defined.
Heartbeat type
The MTA will send a heartbeat to the EMS
Server to let it know it is up and running. A
Data Tunnel between the EMS and MTA is
used, and this can be encrypted or not,
depending on the Option type chosen.
Below are the current Heartbeat types:
2 = Plain text tunnel formatted.
3 = Encrypted text – a shared secret key
between the EMS and MTA must be
configured on both the MTA and EMS.