EonNAS Pro 500 / 800 Hardware Manual
48
5.2 System Error Buzzer
Note:
The LCD module provides basic action(s) and monitoring statuses only, it is
recommended that in an event of an error, users log into the web-interface to get a
better picture of the overall system statuses!
If your EonNAS Pro system has encountered an error, a single beep buzzer alarm will
sound continuously until you manually turn it off and a “Mute Buzzer -> Yes No”
prompt will show on the LCD module. With the arrow pointed at “Yes”, press the
“ENTER” button to turn off the buzzer.
Once an error has occurred, users must log into the web interface and check the
system logs to identify the issue(s). Below is a list of the possible triggering events and
simple countermeasures.
1.
CPU or system temperature
exceeded the threshold limit:
When you have determined the CPU or system temperature is the
cause of the system error, please check for obstructions in front of and
behind the system enclosure to ensure normal airflow is sustained. If
error persists, please contact
2.
System fan
failure:
When you have determined the system fan has completely failed or is
operating below its normal rev range, please contact
3.
Hard drive failure:
When you have determined a hard drive or hard drive(s) have failed.
Press the “ENTER” button with the arrow pointed at “Yes” to mute the
buzzer.
SELECT
EN TER
EonNAS
M u t e B u z z e r ?
- > Y e s N o
Open the front system panel cover and check all hard drive status LEDs. Normal
operation hard drive’s power status LED should light up green, failed hard drive