19
y
Trigger
: Select the corresponding output, press
Ǐ
ENT
ǐ
key, the
status becomes "
9
". The selected output port generates alarm
trigger message when there's motion detection alarm.
Press "Save" to save the parameter setting, and "Exit" to return to
"Channel" interface.
(7)
Copy and save
Refer to "(5) Save" of "Video mask alarm" in section 4.5.1.
4.5.2 Alarm Input
The DVR supports 16 channels alarm input. Each input can set
schedule time, alarm name, alarm type and linkage separately.
Enter the "Alarm" menu interface, and switch to Alarm input"
option to enter the alarm input setting interface via
Ǐ
WIDE
ǐ
key, as
shown in Figure 4-10.
Figure 4-10
1.
Select alarm inpu
t
Move the cursor to the alarm input, set a corresponding alarm input
number, and set the alarm type. The default setting is normal open.
2.
Set Schedule
Refer to "(3) Set schedule" of "Video mask alarm" in section 4.5.1.
3.
Set alarm linkage
Refer to "(6) Set alarm linkage" of "Video motion detection" in
section 4.5.1.
4.
Copy and save
Select the drop-down list of "Copy to", and press
Ǐ
ENT
ǐ
key.
Select the target channel, and move the cursor to "Copy" button,
press
Ǐ
ENT
ǐ
key to o copy the current parameters setting
temporarily, then move the cursor to "Save" button, and press
Ǐ
ENT
ǐ
key to copy the parameters to other channels. Exit the
menu without save, the copy of parameters is not successful.
After the settings above, alarm linkage will activate when there's
alarm input.
4.5.3 Abnormity Alarm
Abnormity alarm includes hard disk full, hard disk error, network
cable disconnected (reserved), unauthorized access and network
conflict alarms. Users can response quickly to system abnormities
with the help of abnormity alarm.
1.
Select alarm type
Move the cursor to "Type" of abnormity alarm, and press
Ǐ
ENT
ǐ
key to drop down the list, and select corresponding alarm type.
2.
Output setting
Move the cursor to the output check box, and press
Ǐ
ENT
ǐ
key, the
status becomes "
9
". Refer to "Set alarm output" of "Video mask
alarm" in section 4.5.1 for the setting of "audible warning", "control
center" and "Trigger alarm output".
3.
Copy and save
After finishing setting, move the cursor to "Copy", and press
Ǐ
ENT
ǐ
key to copy the current parameter setting temporarily, then
move the cursor to "Save" button, and press
Ǐ
ENT
ǐ
key to copy the
parameters to other channels. Exit the menu without save, the copy
of parameters is not successful.
4.6 Alarm Management
1. Alarm status
After enter "Alarm management" menu, enter "Alarm status" menu
directly, as shown in Figure 4-11.
Figure 4-11
Note
: The interface shows all 16 channels alarm status and alarm
input status. The different icon of each channel indicates the status,
as follows:
Table 1 Icon introduction for alarm status indicators
Indicator
Icon
Color Status
Yellow
Normal (No alarm)
Gray
Video
loss
Green
Motion
detection
Reserved Video
mask
Red
Alarm
input
2. Alarm handling
(1)
Clear a single alarm
Follow the following method to clear the alarm when there's alarm:
Move the cursor to the channel indicator that need to clear the
Summary of Contents for V3060 Series
Page 6: ......