9
SMT-BD1/m
Chapter 2 - Specifications
Compliance with the standards:
CE
approval for
- EMC standards
multi-axis operation in the BF rack with mains
Immunity: CEI standards 801- 2 - 3 - 4
filter BF35 or 70 or in single-axis racks BM20A or
Conducted and radiated disturbances: EN 55011,
BMM05F/05AF with filters FN 612-20/06 or
Group 1, class A
FN 356-16/06 or BF-35. 360° shield and
- Electrical standards for industrial machines:
equipotential according to the wiring rules
EN 60204.1:
- Insulator
:
1500 VAC/1 min.
- Leakage current > 3 mA
(EMI
filters)
Temperature
* storage - 20°C to + 70°C
* operation 5°C to +40°C
From
40°C
on,
the rated currents must be reduced
of 3 %/°C.
Max.
temperature:
50°C
1.2 - Current ratings for 400 VAC drive version
Operating
voltage 565
V
DC
(480 V
DC
< DC bus < max. 685 V
DC
)
Auxiliary
supply
voltage
310
V
DC
(200 V
DC
< Uaux < 340 V
DC
)
Motor phase-phase output voltage
380 Vrms for 565 V
DC
bus
Output current ratings in pulse current mode (I
2
t protection in "fusing" mode)
DRIVE
TYPE
Urated
(Vrms)
Imax
(Arms)
Max. authorized rated current (Arms)
of the drive
1 s
No fan*
Fan 2*
SMT-BD1/m-400/15
400
15.5
5
7.5
SMT-BD1/m-400/30
400
30
8
15
SMT-BD1/m-400/45
400
48
10
19
SMT-BD1/m-400/60
400
60
not used
28
Output current ratings in pulse current mode (I
2
t protection in "limiting" mode)
DRIVE
TYPE
Urated
(Vrms)
Imax
(Arms)
Max. authorized rated current (Arms)
of the drive
1 s
No fan*
Fan 2*
SMT-BD1/m-400/15
400
15.5
not used
5
SMT-BD1/m-400/30
400
30
not used
10
SMT-BD1/m-400/45
400
48
not used
15
SMT-BD1/m-400/60
400
60
not used
23
Maximum room temperature: 40°C, fan type 2: 90 l/s.
Minimum inductance between phases
2 mH
Compliance with the standards:
CE
approval for
- EMC standards
multi-axis operation in the BF rack with mains
Immunity: CEI standards 801- 2 - 3 - 4
filter BF-400/35 or 400/70.
Conducted and radiated disturbances: EN 55011,
360° shield and equipotential according to the
Group 1, class A
wiring rules.
- Electrical standards for industrial machines:
EN 60204.1:
- Insulator
:
2500 VAC/1 min.
- Leakage current > 3 mA
(EMI
filters)
Temperature
* storage - 20°C to + 70°C
* operation 5°C to +40°C
From
40°C
on,
the
rated currents must be reduced
of 3 %/°C.
Max.
temperature:
50°C