55
SMT-BD1/m
Appendix
CAUTION
In
Fusing mode, the amplifier Rated current value must be adjusted in order to be lower or equal to the Maximum
authorized rated current of the amplifier (
Current limitation in
Limiting
mode
When the amplifier RMS current (I
2
t) reaches 85 % of the
Rated current
, the Idyn signal output is activated and
the I
2
t error display is blinking on the amplifier front panel. When the RMS current (I
2
t) drops below 85 % of the
Rated current
, the Idyn signal and the blinking I
2
t error display are both cancelled.
When the amplifier RMS current (I
2
t) reaches the
Rated current
value, the I
2
t protection limits the amplifier
current at this value.
The amplifier current limitation diagram in an extreme case (motor overload or locked shaft) is shown below:
t0
t1
t2
Rated current
Maximum current
Amplifier current
t1 = blinking display
t2 = current limitation
Time
The maximum current duration before the release of the Idyn signal output (t1 - t0) and before limitation at the
rated current (t2 - t0) is calculated the same way as for the
Fusing
mode.
The I
2
t signal threshold values and the amplifier RMS current value on the digitizing oscilloscope, are also
calculated the same way as for the
Fusing
mode.
CAUTION
In
Limiting mode
, the amplifier
Rated current
value must be adjusted in order to be lower or equal to the
Maximum authorized continuous current
of the amplifier