
27
SMT-BD1/m
Chapter 6 - Commissioning
In case of loud noise in the motor at standstill or when running, check the rigidiy of the transmission between
motor and load (backlashes in gearings and couplings). If necessary, renew the
Auto-tuning
procedure by
selecting a lower bandwidth. If the problem remains, renew the
Auto-tuning
procedure while activating the
antiresonance filter.
4.3 - SAVING THE DRIVE PARAMETERS
Save all the parameters in the EEPROM by means of the function
Save parameters to EEPROM
.
4.3.1 - INPUTS - OUTPUTS CONFIGURATION
Open the window "Position application setup" by means of the shortcut button
Window "Inputs - Outputs Configuration".