53
SMT-BD1/m
Appendix
5.2.2 - CURRENT LOOPS ADJUSTMENT ON DRIVES WITH 220 VAC SUPPLY
Select the current loop jumpers corresponding to the motor and drive specifications (position B1, B2 or B3).
On the MAVILOR motor series BL and MA, the current loops adjustments are made according to the table below:
Drive
4 A
8 A
12 A
17 A
30 A
45 A
60 A
70 A
100 A
Motor
MA 3
B1
MA
6
B1
B1
MA
10 B2 B1 B1 B1
MA
20 B2 B1 B1 B1 B1 B1
MA
30
B2 B2 B2 B1 B1
MA
45
B2 B2 B1 B1 B1
MA
55
B2
B2
B2
B1
BL
55-3
B1
BL
55-5
B1
BL
71
B2
BL
72
B2
B1
B1
BL
73
B2
B2
B1
BL
74
B2
B2
B1
BL
111
B1
B1
BL
112 B2 B2 B1 B2
BL
113 B3 B3 B2 B2 B2
BL
114
B3
B3
B2
B2
BL
115
B3 B3 B2 B2 B2
BL
141
B2 B2 B2 B1 B1
BL
142
B3 B3 B2 B2 B1
BL
143
B3 B2 B2 B1 B1 B1
BL
144
B2 B2 B2 B1 B1 B1
On other motor types, the current loops are adjusted according to the
drive current rating
and to
the
inductance between the motor terminals
like follows:
4 A, 8 A, 12 A AND 17 A DRIVES
- Calculation
of
G = 1.4 x Drive current rating (A) x Inductance between phases (mH).
- If
G < 60
, current loop jumpers (x3) on
B3
position.
- If
60 < G < 100
, current loop jumpers (x3) on
B2
position.
- If
G > 100
, current loop jumpers (x3) on
B1
position.
30 A, 45 A, 60 A, 70 A AND 100 A DRIVES
- Calculation
of
G = 1.4 x Drive current rating (A) x Inductance between phases (mH).
- If
G < 100
, current loop jumpers (x3) on
B3
position.
- If
100 < G < 250
, current loop jumpers (x3) on
B2
position.
- If
G > 250
, current loop jumpers (x3) on
B1
position.
5.3 - I
2
t PROTECTION
Current limitation in
Fusing
mode
When the amplifier RMS current (I
2
t) reaches 85 % of the
Rated current
, the Idyn signal output is activated and
the I
2
t error display is blinking on the amplifier front panel. If the RMS current (I
2
t) has not dropped below 85 % of
the
Rated current
within 1 second, the I
2
t fault is released and the amplifier is disabled (otherwise, the Idyn signal
and the blinking I
2
t error display are both cancelled).
When the amplifier RMS current (I
2
t) reaches the
Rated current
value, the I
2
t protection limits the amplifier
current at this value.
The amplifier current limitation diagram in an extreme case (motor overload or locked shaft) is shown below.