High-G Accelerometer settings
By selecting the
Acclerometer (High G)
configuration option from the sensor tree, the high-g
accelerometer settings can be edited, as shown in Figure 28:
•
Enabled
: Enables sampling of the high-g accelerometer.
•
Transmit Data & Log to Flash
: If the high-g accelerometer is enabled, data is transmitted
and logged to flash when required (see Section 4.8.1 for global transmission settings and
Section 4.4.1 to start a flash log).
•
Sampling Rate (Hz)
: The sampling rate of the high-g accelerometer (maximum 1000 Hz).
•
Range (g)
: Sets the maximum acceleration the high-g accelerometer can measure. Sup-
ported options are: ±100, 200 and 400 g. A lower range has a higher sensitivity.
•
Calibration
: Advanced option that adjusts the scaling and offset of each axis.
Figure 28: High-G Accelerometer Settings
Page 36 of 60