 3 

 3 

Contents 

 

So ware Installa on 

 

System Requirements   

 

 

 

 

 

 

 

 

Page 4 

 Installa on Steps 

 

 

 

 

 

 

 

 

 

Page 4 

 

Using the So ware 

 

General Overview 

 

 

 

 

 

 

 

 

 

Page 7 

 File 

Menu

 

 

 

 

 

 

 

 

 

 

 

Page 8 

 Controller 

Menu

 

 

 

 

 

 

 

 

 

 

Page 8 

 

Preferences Menu 

 

 

 

 

 

 

 

 

 

Page 9 

 

Data Menu 

 

 

 

 

 

 

 

 

 

 

Page 9 

 

Help Menu 

 

 

 

 

 

 

 

 

 

 

Page 9 

 

 

Stage1 Tab

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setup   

 

 

 

 

 

 

 

 

 

Page 10 

 

 

Nitrous  

 

 

 

 

 

 

 

 

 

Page 11 

 

 

Fuel 

 

 

 

 

 

 

 

 

 

 

Page 13 

 

 

Stage2 Tab

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setup   

 

 

 

 

 

 

 

 

 

Page 15 

 

 

Nitrous  

 

 

 

 

 

 

 

 

 

Page 16 

 

 

Fuel 

 

 

 

 

 

 

 

 

 

 

Page 18 

 

 

Timer Stage1 Tab 

 

 

 

 

 

 

 

 

 

Page 20 

 

 

Timer Stage2 Tab

 

 

 

 

 

 

 

 

 

 

Page 21 

 

 

Relay Output Tab 

 

 

 

 

 

 

 

 

 

Page 22 

 

 

Con

fi

gura on Tab 

 

 

 

 

 

 

 

 

 

Page 23 

 

 

Data Tab 

 

 

Data Setup 

 

 

 

 

 

 

 

 

 

Page 24 

 

 

Data Chart 

 

 

 

 

 

 

 

 

 

Page 24 

 

Controller Installa on 

 

Wiring Diagram  

 

 

 

 

 

 

 

 

 

Page 25 

 Transmission 

Brake/Clutch 

Input 

Wiring 

       Page 

26 

 RPM/Tachometer 

Input 

Wiring 

        Page 

26 

 

12 Volt Timer Output Wiring 

 

 

 

 

 

 

 

Page 27 

 

12 Volt Timer Output Wiring 

 

 

 

 

 

 

 

Page 27 

 Relay 

Ground 

Output 

Wiring 

        Page 

27 

 

Controller Firmware Update 
 

Update Controller Firmware 

 

 

 

 

 

 

 

 

Page 28 

 

Appendix A—Se ng up the controller for a run 

 

 

 

 

 

 

Page 30

 

 

Appendix B—Typical procedure when making a run 

 

 

 

 

 

Page 31

 

 

Appendix C—Retrieving data log a er a run 

 

 

 

 

 

 

Page 32

 

 

 

 

 

Summary of Contents for NPC-2006

Page 1: ...NPC 2006 Nitrous Power Controller Induction Solutions 16121 Flight Path Dr Brooksville FL 34604 352 593 5900 Phone 352 593 5901 Fax email info inductionsolutions com...

Page 2: ...buse improper opera on lack of reasonable care or all previously stated reasons due to in compa bility with other manufacturer s products Induc on Solu ons assumes no responsibility or liability for d...

Page 3: ...Page 21 Relay Output Tab Page 22 Configura on Tab Page 23 Data Tab Data Setup Page 24 Data Chart Page 24 Controller Installa on Wiring Diagram Page 25 Transmission Brake Clutch Input Wiring Page 26 RP...

Page 4: ...dows 7 all versions Windows 8 x all versions Windows 10 all versions So ware Installa on Steps The Nitrous Power Controller so ware is located on the USB flash drive included with the NPC 2006 kit Plu...

Page 5: ...5 5 Le click on the Induc on Solu ons Drive Double click on NPC 2006_Setup...

Page 6: ...lla on program to complete On the Windows desktop you will find a Nitrous Power Controller icon Double click to start the so ware Note When the so ware is installed a link to start the so ware will al...

Page 7: ...vides visual feedback for read and write opera ons to the controller through the USB interface USB connec on status this indicates a valid USB connec on has been established with the controller Firmwa...

Page 8: ...setup data from the controller to the Nitrous Power Controller so ware Note a er downloading the setup data from the controller you may use the File Menu Save File selec on to save the setup data to a...

Page 9: ...default setup will opened Data Menu Help Menu Open Data Log File open a data log file that has been previously saved to the computer Save Data Log File save data log informa on to a file on the comput...

Page 10: ...t the Stage1 Nitrous Sole noid Pulse Frequency se ng The controls to adjust individual solenoid output frequencies will be disabled when this se ng is On Stage1 Synchronize Pulse Frequency the Stage1...

Page 11: ...the graph to clear the anchor point Once the graph is the ac ve control click on graph the keyboard may also be used to edit the data points CTRL S set edit point to center of graph data Le and Right...

Page 12: ...e user to adjust how quick the nitrous comes back on if the Ac va on signal is removed Example 10 per pulse would increase the rate 10 for each pulse star ng at the Resume Start Percent se ng 35 Resum...

Page 13: ...the anchor point Once the graph is the ac ve control click on graph the keyboard may also be used to edit the data points CTRL S set edit point to center of graph data Le and Right keys move the curre...

Page 14: ...lows the user to adjust how quick the fuel comes back on if the Ac va on signal is removed Example 10 per pulse would increase the rate 10 for each pulse star ng at the Resume Start Percent se ng 35 R...

Page 15: ...alid range 1000 to 16 000 RPM in 10 RPM increments Stage2 Synchronize Pulse Frequency the Stage2 nitrous and fuel solenoids can be configured to func on at the nitrous sole noid frequency hertz only b...

Page 16: ...ear the anchor point Once the graph is the ac ve control click on graph the keyboard may also be used to edit the data points CTRL S set edit point to center of graph data Le and Right keys move the c...

Page 17: ...Resume Start Percent to build a Resume Ramp This allows the user to adjust how quick the nitrous comes back on if the Ac va on signal is removed Example 10 per pulse would increase the rate 10 for eac...

Page 18: ...in the graph to clear the anchor point Once the graph is the ac ve control click on graph the keyboard may also be used to edit the data points CTRL S set edit point to center of graph data Le and Rig...

Page 19: ...the Resume Start Percent to build a Resume Ramp This allows the user to adjust how quick the fuel comes back on if the Ac va on signal is removed Example 10 per pulse would increase the rate 10 for e...

Page 20: ...able which control parameters are used to deter mine when the Stage1 Timer 12V output will be On This output supplies 12V when On Any op ons that are selected are combined to determine if the output s...

Page 21: ...e un checked o for these features to be enabled Timer Stage1 Configura on check to enable which control parameters are used to deter mine when the Stage1 Timer 12V output will be On This output suppli...

Page 22: ...sed on Engine RPM Valid range 0 to 16000 in 10 RPM increments Stage2 Nitrous Percent these se ngs control the output based on Stage2 Nitrous Percent Valid range 0 0 to 100 0 in 1 Percent increments St...

Page 23: ...er is Ac vated Before the controller is Ac vated the clutch input is recognized in real me with no delay This se ng could be used to ignore shi s with a manual transmission 1 second or a very low se n...

Page 24: ...ng determines the Engine RPM when the controller begins recording data Valid range 1 000 to 10 000 in 10 RPM increments Data Tab Data Chart Data Log Navaiga on and keyboard shortcut keys Right and Le...

Page 25: ...25 25 Wiring Diagram 12V Input Required This relay is included with the kit...

Page 26: ...manufacturer instruc ons for more informa on Cau on never connect the white tach signal wire directly to the coil nega ve wire with a mul spark igni on Connect white tach signal wire here when not usi...

Page 27: ...r to ground so the output is not floa ng when in the o state If your igni on and or igni on ming controller is ac vated by a 12 volt signal the 20ga Purple Stage2 Output wire can be connected directly...

Page 28: ...ackup copy will be made Important do not turn o power to the controller or unplug the USB cable during the update process If this does occur the controller will remain in update mode and when the USB...

Page 29: ...while the controller update con nues 6 when prompted select the new firmware file to load and click on Open 8 when the firmware update process is complete click on Ok 7 please be pa ent while the con...

Page 30: ...he lower le corner to confirm download progress D Click on OK when the download complete message is displayed E Edit the setup as desired F The setup may be saved to the PC using File Save File or op...

Page 31: ...lutch Input will be ignored a er the ini al launch for the amount of delay me set for this feature E Stage the vehicle and launch F The data log will begin recording once the data recording ac va on c...

Page 32: ...up can be loaded from the data log at a later date For example you return to a track and want the same setup that was used on a previous run See below for instruc ons to retrieve the setup from a data...