Speci
fi
cations
78
Suitable tap water pressure range
0.1 (
fl
ow pressure) – Maximum water pressure 0.75 (hydrostatic pressure) MPa
Suitable toilet and
fl
ushing method
REGIO, air drive method
Rated power
120 VAC, 60 Hz
Rated power consumption
700 W
Amount of
fl
ushing water
1.6 GPF (6 L) for full
fl
ush, 1.1 GPF (4 L) for partial
fl
ush
Product dimensions
18
1
/
8
in (460 mm) (W) x 30
1
/
2
in (775 mm) (D) x 24 in (610 mm) (H)
Product weight
Approx. 141 lbs (64 kg) (approx. 31 lbs (14 kg) for the function unit and approx. 110 lbs (50 kg) for the toilet)
Wall-mounted remote control unit
10 in (257 mm) (W) x 1 in (25 mm) (D) x 3
1
/
8
in (80 mm) (H)
2 AA alkaline batteries are used.
Clock accuracy
/-1 minute per month at room temperature 77 °F (25°C)
W
ashing
Warm water supply system:
Tank capacity
Hot water storage type: Approx. 0.53 GPF (2 L)
Nozzle
Motor-drive nozzles for front washing and rear
Nozzle hole
For front: f1.8 x 1 For rear: f1.0 x 10
Water
consumption
for front
washing
Power washing
0.17 – 0.37 GPM 0.65 – 1.4 L/min (adjustable to 6 levels)
Mild washing
0.12 – 0.24 GPM 0.45 – 0.9 L/min (adjustable to 6 levels)
Water consumption for rear
0.21 – 0.40 GPM 0.8 – 1.5 L/min (adjustable to 6 levels)
Water supply method
Direct connection with tap water
Water heater capacity
600 W
Water temperature control
OFF (water temperature) and adjustable to 6 levels within the range from Low (approx. 90 °F (32 °C))
to High (approx. 104 °F (40 °C))
Safety device
Temperature fuse, high-temperature sensor switch, and
fl
oat switch
Drying with warm air
Air
fl
ow
10.5 CFM (0.3 m
3
/min) (DC sirocco fan: 12 VDC)
Air heater capacity
380 W
Air temperature control
Low (room temperature), Mid, and Hi (thermistor control)
Safety device
Temperature fuses (2)
Toilet seat, lid
Heater capacity
48 W
Surface temperature
OFF (room temperature) and within the range from Low (approx. 82 °F (28 °C)) to High (approx.
104 °F (40 °C))
Temperature control
Adjustable to 6 levels (with microcomputer control and seat heater auto OFF function) (thermistor control)
Safety device
Temperature fuse
Deodorizing function
Deodorizing method
Chemical absorption by deodorizer cartridge
Deodorizer cartridge life
Approx. 7 years
Deodorizing capacity
Power mode: 3.9 CFM (0.11 m
3
/min), Full-power mode: 4.9 CFM (0.14 m
3
/min), Turbo mode: 6.0 CFM (0.17 m
3
/min)
Fan type
Sirocco fan
Filter
Built into the top cover
Plasmacluster
Air
fl
ow
105 CFM (3 m
3
/min)
Fan type
Sirocco fan
Anti-bacteria ion operation mode
Automatic switch between clean mode and refresh mode
Filter
Built into the top cover
Music play
No. of music tracks
29
Output
0.25 W x 2 (stereo)
Speaker
2 W
Memory
SD memory card
Music format
MP3
Power save
Advanced power save (power save for 24 hours), one-touch power save (automatic reset after 8 hours)
Sensor
Occupied seat sensor: Infrared distance-measuring sensor Body sensor: Infrared distance-measuring sensor
Power cord
Effective length: 3 ft (1.0 m)
Operating temperature range
32 °F – 104 °F (0 °C – 40 °C)
Speci
fi
cations
Speci
fi
cations
Summary of Contents for Regio DV-R115-VL-US