Cleaning and Maintenance
67
Periods of Non - Use
In the following cases, be sure to drain the toilet and disconnect the power plug from the outlet.
●
When the toilet is not used for extended periods of time (such as a vacation, or in a vacation home installation), the
power cord should be disconnected and the water drained from the toilet.
How to Drain the Toilet
■
If Freezing Weather is Anticipated
●
Drain the water in the toilet bowl and
fi
ll the bowl with
anti-freeze. An empty toilet bowl will allow sewer gases
to enter the bathroom.
●
The water supply pipes in the houses should be drained.
Close the water shutoff valve.
Remove the top cover.
Remove the strainer.
Check that no water leaks from the water
shutoff valve.
Mount the top cover.
Mount the strainer.
Strainer
Connect the water supply hose.
* See page 68 for more information on connecting
the water supply hose.
Disconnect the water supply hose from
the water shutoff valve and drain water
from inside the hose.
* See page 68 for more information on
disconnecting the water supply hose.
Water supply hose
Water shutoff valve
Clip ring
Press the MASSAGE and NOZZLE
POSITION REAR buttons simultaneously
for 2 seconds.
* The warm water in the tank will be drained.
* This process takes about 20 minutes to complete.
Turn the manual lever (red)
counterclockwise approximately 180°.
Turn (counterclockwise)
Manual lever (red)
■
When using the toilet again, be sure to perform
usage checks described on page 15.
M NOZZLE POSITION: REAR
Strainer
Flat screwdriver
Flat screwdriver
Disconnect the power cord from the
outlet.
Close
Water shutoff valve
Water shutoff valve handle