37
37
CAUTION
When removing the strainer, be sure to close the
water shutoff valve. When installing the strainer,
tighten it fully until the line is hidden by the body.
* Failure to do so could result in water leakage.
2. Drain the water from the tank using
the flush lever.
Draining the water and disconnecting the power
1. Close the water shutoff valve to stop
the flow of water.
Water shutoff valve
Turn clockwise.
5. Remove the warm water tank drain
plug and drain the water from the
warm water tank.
4. Drain the water from the water supply
hose.
Strainer
Turn counterclockwise.
Strainer
③
Remove the body from the toilet. (See page 33.)
④
Tilt the body and drain out the water from inside
the body water supply hose through the strainer
installation opening.
Water supply hose
①
Place a wash bowl or similar container underneath
the strainer.
②
Remove the strainer with a screwdriver or similar tool.
3. Remove the power plug from the wall
outlet.
①
Loosen the water drain plug on the body of this
product by turning it counterclockwise 90 degrees.
⑤
After draining out the water, close the strainer
tightly with a screwdriver or similar tool.
Turn counterclockwise 90°
②
Pull out the water drain plug, tilt the body forward,
and drain all the water out of the warm water tank.
③
After draining out the water, turn the water drain
plug clockwise 90 degrees to close it.
④
Install this product onto the toilet bowl. (See page
34.)
Turn clockwise 90°
Do not attempt to drain the water out of this
product with the body sitting as it is.
* Water could penetrate inside this product
mechanism and cause damage.
CAUTION
Warm water tank
drain plug
Tighten the strainer until the
line is hidden inside the body.
Line
6. When using the toilet again, be sure to
perform a trial operation (See page 16.)
WARNING
When not using this product for an extended time, be sure to
drain the water from this product.
* The water in this product could freeze and cause damage,
resulting in electric shock, fire and water leakage.
* The water could become dirty and cause skin inflammation.
If this product will not be used for an extended time (such as when you are away on a long trip), use the
following procedure to drain the water from of this product.
Draining this product for periods of extended disuse
CAUTION:
Water left in this product for an extended period can become contaminated and clog this
product, or can freeze. In either case, this product could be damaged.
GCW-1220-W-08110.indd 37
GCW-1220-W-08110.indd 37
2011/07/12 11:12:37
2011/07/12 11:12:37
Summary of Contents for CW-RS3-W
Page 1: ...GCW 1220 W 08110 4 indd 1 GCW 1220 W 08110 4 indd 1 2011 07 12 10 50 55 2011 07 12 10 50 55...
Page 2: ...GCW 1220 W 08110 4 indd 2 GCW 1220 W 08110 4 indd 2 2011 07 12 10 50 56 2011 07 12 10 50 56...
Page 3: ...GCW 1220 W 08110 4 indd 3 GCW 1220 W 08110 4 indd 3 2011 07 12 10 50 56 2011 07 12 10 50 56...