7
A ground fault circuit interrupter must be installed in the circuit that supplies power to this product.
Ground fault circuit interrupter
Power supply
Grounding
Installation location
Water supply
220V
Checking the toilet room
The dimensions required for mounting this product on a
toilet are as shown in the figure below. Check to make
sure there is sufficient space inside the toilet room and
that there are no obstructions in the way.
DANGER:Improper use of the grounding plug can result in a risk of electric hazard.
Use only the tap water line to supply water to this product. There is danger of ground water or other
water that is not tap water causing trouble with this product.
The tap water pressure must be 0.06 to 0.74 MPa (0.6 to 7.5 kgf/cm
2
).
This product is for use on a nominal 220 V circuit. Use a 220 V, 50 Hz power supply. The maximum
power consumption is 305 W. Electrical wiring must be installed that meets these conditions. The plug
outlet shall be placed in accessible location after installation.
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk
of electric hazard by providing an escape wire for the electric current. The power cord has a grounding
wire and a three-blade grounding plug (shown below). Do not use an adapter with the product's power
plug, or use any other method to connect the plug to an improperly configured outlet.
The outlet to which the product is connected must be 220 V, 50 Hz, with a minimum electrical rating of 3
A. The outlet must be properly installed and grounded, and have a three-slot outlet (shown below).
If it is necessary to use an extension cord, use only a three wire extension cord that has a three-blade
grounding plug. The extension cord must be rated for at least 220 V, 50 Hz, 3 A.
This product is manufactured for family or personal use. In order to avoid damage to the electronic
components, prevent the body of this product from getting wet by drops or splashes of water. In
extremely humid conditions, please provide adequate ventilation by operating an exhaust fan or opening
a window (or door).
Unit : cm
3 or more
3 or more
20.7
21.9
120 or more
40 or more
55.8
42.6
GCW-1220-W-08110.indd 7
GCW-1220-W-08110.indd 7
2011/07/12 11:12:12
2011/07/12 11:12:12