Avoid full discharges and charge the battery more often between uses.
l
Avoid storing the communication device in a high temperature (above 86° F / 30° C) area.
Connecting to a Wireless TROLL Com
A Wireless TROLL Com can be used to connect the instrument to software if the sonde is deployed on a cable.
1. Turn on the Wireless TROLL Com.
2. Make sure the cable is connected to the instrument as well as the communication device.
3. Go to Bluetooth settings on your mobile device or computer.
4. From the Bluetooth section, search for devices.
5. Tap or click the serial number of the communication device to pair the device with the phone or computer. The
serial number is located under the USB flap.
Connecting to VuSitu
1. Open the VuSitu Mobile App. If you have correctly paired your Wireless TROLL Com with your wireless device,
and the instrument is available, the software will connect and display readings.
If the Searching screen continues to show, tap "Choose another device" and select the device
you are trying to connect to.
Connecting to Win-Situ 5
1. Open Win-Situ 5 Software.
2. When prompted, "Connect to device now?" click
No
.
3. Plug the USB charging cable into the computer and Wireless TROLL Com.
4. Click
Preferences
, then click
Comm Settings
.
5. Select the correct Com port used by the charging cable, then select the communication settings for the instrument
you are connecting. The following default communication settings are most common for In-Situ instruments:
l
Baud: 19200
l
Data Bits: 8
l
Parity Bits: Even
l
Stop Bits: 1
l
Device Address: 1
l
Mode: Modbus-RTU
If you cannot connect using these settings, click the "Search for Devices" or "Reset All Devices" button.
6. Click the checkmark, then click the Connect button in the lower right hand corner.
Summary of Contents for Level TROLL 400
Page 51: ...1 800 446 7488 51 www in situ com See the online Help for more details ...
Page 64: ...1 800 446 7488 64 www in situ com Analog 4 20 mA 2 Wire ...
Page 65: ...1 800 446 7488 65 www in situ com SDI 12 3 Wire ...
Page 66: ...1 800 446 7488 66 www in situ com Modbus Master ...
Page 67: ...1 800 446 7488 67 www in situ com Modbus Master with RS232 Converter Required ...
Page 78: ...1 800 446 7488 78 www in situ com Decontamination and Cleaning Form ...
Page 82: ...1 800 446 7488 82 www in situ com Level TROLL 500 Instrument ...
Page 83: ...1 800 446 7488 83 www in situ com Level TROLL 700 Instrument ...
Page 84: ...1 800 446 7488 84 www in situ com TROLL Com Communication Device ...
Page 85: ...1 800 446 7488 85 www in situ com BaroTROLL Instrument ...