![Imperx Tiger T2040 User Manual Download Page 81](http://html1.mh-extra.com/html/imperx/tiger-t2040/tiger-t2040_user-manual_2049011081.webp)
Tiger CCD Cameras with Camera Link
– User Manual
November 27, 2017
Page
81
of
86
Rev 1.0
0x0008
0x0018
0x0028
0x0038
AFE 1 Analog Offset, Ch. A
AFE 1 Analog Offset, Ch. B
AFE 1 Analog Offset, Ch. C
AFE 1 Analog Offset, Ch. D
Data (9:0)
<value>
Data (31:10) N/A
Applies to cameras T6640, T8810, T8820
RW
Sets analog offset.
0x0048
0x0058
0x0068
0x0078
AFE 2 Analog Offset, Ch. E
AFE 2 Analog Offset, Ch. F
AFE 2 Analog Offset, Ch. G
AFE 2 Analog Offset, Ch. H
Data (9:0)
<value>
Data (31:10) N/A
Applies to cameras T8810, T8820
RW
Sets analog offset.
0x0088
0x0098
0x00A8
0x00B8
AFE 3 Analog Offset, Ch. I
AFE 3 Analog Offset, Ch. J
AFE 3 Analog Offset, Ch. K
AFE 3 Analog Offset, Ch. L
Data (9:0)
<value>
Data (31:10) N/A
Applies to camera T8820 only
RW
Sets analog offset.
0x00C8
0x00D8
0x00E8
0x00F8
AFE 4 Analog Offset, Ch. M
AFE 4 Analog Offset, Ch. N
AFE 4 Analog Offset, Ch. O
AFE 4 Analog Offset, Ch. P
Data (9:0)
<value>
Data (31:10) N/A
Applies to camera T8820 only
RW
Sets analog offset.
Digital Gain, Offset, Black Level Correction, Tap Balance
0x0180
Digital Gain
Data (9:0)
<value>
–
digital gain
Data (31:10) N/A
RW
Sets main digital
gain and applies to
both channels. The
step is 0.001x.
0x0184
Digital Offset
Data (9:0)
<value>
–
digital offset
Data (31:10) N/A
RW
Sets main digital
offset and applies to
both channels.
0x0114
Black Level Correction
Data (0)
0
–
disable black level correction
1
–
enable black level correction
Data (31:2)
N/A
RW
Enables black level
correction.
0x0110
Tap Balance
Data (9:0)
00
–
no tap balance
01
–
dynamic automatic tap
balance
10
–
tap balance once
Data (31:10) N/A
RW
Enables tap balance.
If tap balance
“once” is used, set
register every time
from “00” to “10.”
Triggering Registers
Address
Register
Name
Data
Type
Description
0x05BC
Acquisition
Mode
Data (0)
0x1
–
trigger is disabled, free running mode
0x0
–
trigger is enabled
–
camera is in
trigger mode
Data
(31:1)
N/A
RW
Enables or disables the
triggering operation for
all cameras.
0x0508
Trigger
Input
Selector
Data (2:0)
0x0
–
N/A
0x1
–
External 1
–
camera expects trigger
from external source mapped IN 1.
0x2
–
Internal
–
camera expects trigger
from programmable pulse generator.
0x3
–
computer
–
camera expects trigger
from CC1 via camera link cable.
RW
Selects triggering
source.