Tiger CCD Cameras with Camera Link
– User Manual
November 27, 2017
Page
76
of
86
Rev 1.0
Temp.
Register Value
+127.75 °C
01 1111 1111
+0.25 °C
00 0000 0001
0° C
00 0000 0000
-0.25 °C
11 1111 1111
-128 °C
10 000 0000
Miscellaneous
Address
Register Name
Data
Type
Description
0x6000
Power Reset
Data 00000001
WO
Resets the CCD power after ESD
event
0x601C
SW_Reset
Data
0xDEADBEEF
WO
Command initiates software reset
(loads workspace from config
spaces set by Boot From data). You
must write data 0xDEADBEEF to
initiate reset.
0x0604
BAUD Rate
Selector
Data (2:0)
0x0
–
9600
0x1
–
19200
0x2
–
38400
0x3
–
57600
0x4
–
115200 (default)
0x5 to 0x7 - reserved
Data (31:3) N/A
RW
Sets communication baud rate
between camera and computer.
EOS Lens Control Information Registers
(T6640 ruggedized version only)
Address Register Name
Data
Type
Description
0x6200
IRIS Step Value
Data (7:0)
<IRIS Step>
Data (31:8)
N/A
RW
Sets the IRIS step increment value.
0x6204
IRIS Close Step
WO
Closes IRIS one step per command.
The step value is set above 0x6200.
0x6208
IRIS Open Step
WO
Opens IRIS one step per command.
The step value is set above 0x6200.
0x620C
IRIS Close Full
WO
Command fully closes the IRIS.
0x6210
IRIS Open Full
WO
Command fully opens the IRIS.
0x6214
IRIS Stop
WO
Command stops IRIS movement.
0x6218
FOCUS Step Value
Data (7:0)
<FOCUS Step>
Data (31:8)
N/A
WR
Sets FOCUS step increment value.
0x621C
FOCUS Close Step
WO
Closes FOCUS one step per
command. The step value is set
above 0x6218.
0x6220
FOCUS Open Step
WO
Opens FOCUS one step per
command. The step value is set
above 0x6218.
0x6224
FOCUS Near Full
WO
Command sets FOCUS to full near
position.
0x6228
FOCUS Far Full
WO
Command sets FOCUS to full far
position.