![Imperx Tiger T2040 User Manual Download Page 80](http://html1.mh-extra.com/html/imperx/tiger-t2040/tiger-t2040_user-manual_2049011080.webp)
Tiger CCD Cameras with Camera Link
– User Manual
November 27, 2017
Page
80
of
86
Rev 1.0
AEC, AGC, AIC Workspace Registers
Address
Register
Name
Data
Type
Description
0x0150
Auto
Exposure
Control
(AEC)
Data (0)
0x0
–
disable auto exposure control
0x1
–
enable auto exposure control
Data (31:1)
N/A
RW
Enables the auto
exposure control.
0x05B0
Maximum
Exposure
Time Limit
Data (23:0)
<value>
–
maximum exposure time
limit
Data (31:24) N/A
RW
Sets max. exposure time
limit during AEC.
0x05C8
Minimum
Exposure
Time Limit
Data (23:0)
<value>
–
minimum exposure time
limit
Data (31:24) N/A
RW
Sets min. exposure time
limit during AEC.
0x0154
Auto Gain
Control
(AGC)
Data (0)
0x0
–
disable auto gain control
0x1
–
enable auto gain control
Data (31:1)
N/A
RW
Enables auto gain
control.
0x0160
Maximum
Gain Limit
Data (9:0)
<value>
–
maximum analog gain limit
Data (31:10) N/A
RW
Sets max. analog gain
limit during AGC.
0x018C
Minimum
Gain Limit
Data (9:0)
<value>
–
minimum analog gain limit
Data (31:10) N/A
RW
Sets min. analog gain
limit during AGC.
0x0158
Luminance
Level
Threshold
Data (11:0)
<value>
–
desired luminance level
Data (31:12) N/A
RW
Sets luminance level to
maintain during
AEC/AGC.
0x017C
Luminance
Type
Selection
Data (1:0)
0x0
–
average luminance
0x1
–
peak luminance
0x2 or 0x3
–
reserved
Data (31:2)
N/A
RW
Sets luminance mode to
use during AEC or AGC
process.
Gain and Offset Workspace Registers
Address
Register Name
Data
Type
Description
Below: VGA gain, 6dB to 42dB (0.0359 dB per step)
0x0004
0x0014
0x0024
0x0034
AFE 1 Analog Gain, Ch. A
AFE 1 Analog Gain, Ch. B
AFE 1 Analog Gain, Ch. C
AFE 1 Analog Gain, Ch. D
Data (9:0)
<value>
Data (31:10)
N/A
Applies to cameras T6640, T8810, T8820
RW
Sets main analog
gain.
0x0044
0x0054
0x0064
0x0074
AFE 2 Analog Gain, Ch. E
AFE 2 Analog Gain, Ch. F
AFE 2 Analog Gain, Ch. G
AFE 2 Analog Gain, Ch. H
Data (9:0)
<value>
Data (31:10)
N/A
Applies to cameras T8810, T8820
RW
Sets main analog
gain.
0x0084
0x0094
0x00A4
0x00B4
AFE 3 Analog Gain, Ch. I
AFE 3 Analog Gain, Ch. J
AFE 3 Analog Gain, Ch. K
AFE 3 Analog Gain, Ch. L
Data (9:0)
<value>
Data (31:10)
N/A
Applies to camera T8820 only
RW
Sets main analog
gain.
0x00C4
0x00D4
0x00E4
0x00F4
AFE 4 Analog Gain, Ch. M
AFE 4 Analog Gain, Ch. N
AFE 4 Analog Gain, Ch. O
AFE 4 Analog Gain, Ch. P
Data (9:0)
<value>
Data (31:10)
N/A
Applies to camera T8820 only
RW
Sets main analog
gain.
Analog Offset