BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
218 of 265
LUT Select
– selects which of the two supported LUTs will be used.
By default LUT #1 is factory programmed with standard Gamma of
0.45. LUT #1 and LUT #2 can be reprogrammed by the user.
Image
Enables the image enhancement processing features. Seven options
Enhancement:
are available:
Figure 5.19 – Processing window
1.
Disable
– no enhancement operation will be performed.
2.
Single Threshold Binary
– single point threshold operation
will be performed. Set the desired threshold level X1 using the
horizontal (bottom) slider (left portion).
3.
Dual Threshold Binary
– two-point threshold operation will
be performed. Set the desired upper threshold level X2 using
the horizontal (bottom) slider (right portion), and the lower one
X1 – horizontal (bottom) slider (left portion).
4.
Dual Threshold Gray
– two-point threshold operation with
gray scale mid. values will be performed. Set the desired upper
threshold level X2 using the horizontal (bottom) slider (left
portion), and the lower one X1 – horizontal (bottom) slider
(right portion).