BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
170 of 265
Data (31:13)
:
N/A
4.3.6.5
Programmable Frame Time Enable
This register enables a programmable frame time mode. The user can extend
the camera frame time beyond the camera free-running frame time up to ~ 16
seconds. This is also known as long integration.
Address
:
0x0550
Data (0)
:
0 – disable programmable frame time.
1 – enable programmable frame time
Data (31:1)
:
N/A
4.3.6.6
Programmable Frame Time Absolute
This register sets the actual frame time in microseconds.
Address
:
0x0558
Data (23:0)
:
<value> – actual frame time in micro seconds.
Data (31:24)
:
N/A
4.3.6.7
Camera Speed Selection
This register sets the camera speed. Two modes are available – normal and
fast (over-clocked). The free-running frame rate increases in fast mode.
Address
:
0x0608
Data (0)
:
0 – normal speed.
1 – fast speed.
Data (31:1)
:
N/A
4.3.7 AEC, AGC, AIC Workspace Registers
4.3.7.1
Auto Exposure Control (AEC)
This register enables the auto exposure control.
Address
:
0x0150
Data (0)
:
0 – disable auto exposure control
1 – enable auto exposure control
Data (31:1)
:
N/A
4.3.7.2
Maximum Exposure Time Limit
This register sets the maximum exposure time limit during AEC. The
automatic exposure control process will keep the camera exposure always
below the set level. This is to prevent motion smear. The Minimum Exposure
Time Limit is factory preset.