BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
177 of 265
4.3.9.4
Triggering Edge Selector
This register selects the triggering edge – Rising or Falling.
Address
:
0x050C
Data (0)
:
0 – rising edge
1 – falling edge
Data (31:1)
:
N/A
4.3.9.5
Trigger De-bounce Time
This register selects the trigger signal de-bounce time. Any subsequent trigger
signals coming to the camera within the de-bounce time interval will be
ignored.
Address
:
0x0510
Data (2:0)
:
000 – no de-bounce
100 – 10
s de-bounce time
101 – 50
s de-bounce time
001 – 100
s de-bounce time
110 – 500
s de-bounce time
010 – 1.0 ms de-bounce time
111 – 5.0 ms de-bounce time
011 – 10.0 ms de-bounce time
Data (31:3)
:
N/A
4.3.9.6
Trigger Overlap
This register selects the trigger overlap mode. If the camera receives a trigger
pulse while the camera is still processing the previous trigger, the user has the
option to ignore the incoming trigger or to terminate the previous process and
to start a new one.
Address
:
0x0514
Data (1:0)
:
00 – ignore the next trigger
01 – accept only after the exposure is completed
10 – accept at any time
11 – N/A
Data (31:2)
:
N/A
4.3.9.7
Triggering Mode Selection
This register selects the triggering mode.
Address
:
0x0518
Data (3:0)
:
0x0 – standard triggering
0x1 – fast triggering