11 – 4x speed – fast
Data (31:2)
:
N/A
4.3.7.5.
Auto Gain Control (AGC)
This register enables the auto gain control.
Address
:
0x0154
Data (0)
:
0 – disable auto gain control
1 – enable auto gain control
Data (31:1)
:
N/A
4.3.7.6.
Maximum Gain Limit
This register sets the maximum analog gain limit during AGC. The
automatic gain control process will keep the camera analog gain always
below the set level.
Address
:
0x0160
Data (9:0)
:
<value> – maximum analog gain limit
Data (31:10)
:
N/A
4.3.7.7.
Minimum Gain Limit
This register sets the minimum analog gain limit during AGC. The
automatic gain control process will keep the camera analog gain always
below the set level.
Address
:
0x018C
Data (9:0)
:
<value> – minimum analog gain limit
Data (31:10)
:
N/A
4.3.7.8.
Gain Correction Speed
This register sets the gain correction speed during AGC. The automatic
gain control process can set the algorithm convergence speed, i.e. how long
it takes to reach the desired gain.
Address
:
0x0178
Data (1:0)
:
00 – 1x speed – slow
01 – 2x speed
10 – 3x speed
11 – 4x speed – fast
Data (31:2)
: