BOBCAT HD-SDI
Hardware User’s Manual
Imperx, Inc.
Rev. 1.4
6421 Congress Ave.
6/2/2014
Boca Raton, FL 33487
+1 (561) 989-0006
78 of 175
Address
:
0x6074
4.3.2.7.
Save to User #2
The
‘Save To User #2’
command instructs the camera to save its
workspace to the user #2 space. All current workspace settings will be
saved to the user #2 space. This is a command, not a register. The act of
writing to this location initiates the save to user #2 space.
Address
:
0x6078
4.3.2.8.
SW_Reset
The
‘SW_Reset’
command instructs the camera to initiate software reset,
which resets the camera and loads its workspace from one of the
configuration spaces as determined by the ‘Boot From’ data.
Although,
this is a command, the user MUST write a specific data 0xDEADBEEF in
order to initiate the reset sequence.
Address
:
0x601C
Data
:
0xDEADBEEF
4.3.2.9.
BAUD Rate Selector
This register sets the communication baud rate between the camera and
computer.
Address
:
0x0604
Data (2:0)
:
000 – 9600
001 – 19200
010 – 38400
011 – 57600
100 – 115200 (default)
Data (31:3)
:
N/A
4.3.3.
Retrieving Manufacturing Data
The camera contains non-volatile memory that stores manufacturing related
information. This information is programmed in the factory during the
manufacturing process.
4.3.3.1.
Firmware Revision
These registers return the camera main firmware revision.
Main FW revision
Address
: 0x6004