BOBCAT HD-SDI
Hardware User’s Manual
Imperx, Inc.
Rev. 1.4
6421 Congress Ave.
6/2/2014
Boca Raton, FL 33487
+1 (561) 989-0006
132 of 175
H&V Lines
– superimposes a pair of H and/or V lines. Dual
sliders are available to select the horizontal and vertical
position of the lines. Each line location will be visible in the
gray square window. The sliders range from 1 to the
maximum number of pixels/lines available on the sensor.
Brightness
– sets the brightness of the crosshair and H&V
lines, ranges from 0 to 4095.
Scale
– provides the ability to measure distance between the
lines in pixels or in linear units. The uses must enter a scale
calibration value.
5.7.6.
Area of Interest (AOI)
AOI is used to select one or more regions of interest. A total of seven
independent AOIs can be generated, and the user can select the size of each
horizontal and vertical window. Horizontal and Vertical binning is also
available to change the H and V resolution of the image – Figure 5.15.
Figure 5.15 – AOI window.
AOI#:
Bobcat supports up to six slave independent horizontal and
vertical regions of interest could be enabled. If slave AOIs is to
be used MAOI MUST be enabled. All slave AOIs have to be
positioned within the MAOI. The slave AOIs can be set to be
included or excluded from the MAOI After enabling the
selected AOI, the user can enter the desired region of interest by
setting the active window size (Width, Height) and offset (X,
Y). Image location (1.1) is top left corner. The user can set the