BOBCAT HD-SDI
Hardware User’s Manual
Imperx, Inc.
Rev. 1.4
6421 Congress Ave.
6/2/2014
Boca Raton, FL 33487
+1 (561) 989-0006
76 of 175
x01 – Invalid command. An invalid command (not 52 or 57) has been sent
to the camera.
x02 – Time-out.
x03 – Checksum error
x04 – Value less then minimum
x05 – Value higher than maximum
x06 – AGC error
x07 – Supervisor mode error
x08 – Mode not supported error
4.3.
CAMERA CONFIGURATION REGISTER DESCRIPTION
4.3.1.
Startup Procedure
Upon power on or receipt of an
‘SW_Reset’
command, the camera performs
the following steps:
1.
Boot loader checks Program FLASH memory for a valid Firmware image
and loads it into the FPGA.
2.
The camera reads the ‘Boot From’ register from the parameter FLASH and
loads its workspace from one of the configuration spaces as determined by
the ‘Boot From’ data. The available configuration spaces are:
‘Factory…’,
‘User #1…’, ‘User #2…’
3.
The camera is initialized and ready to accept user commands.
4.3.2.
Saving and Restoring Settings
Operational settings for the camera may be stored for later retrieval in its non-
volatile memory. Three separate configuration spaces exist for storing these
settings: ‘factory’ space, ‘user #1’ space and ‘user #2’ space. The factory space
is pre-programmed by factory personnel during the manufacturing process.
This space is write protected and cannot be altered by the user. Two user
spaces are also provided allowing the user to store his/her own preferences.
The camera can be commanded to load its internal workspace, from either of
the three configuration spaces, at any time. The user can also define from
which space the camera should automatically load itself following a power
cycle or receipt of a reset (
‘SW_Reset’
) command.
4.3.2.1.
Boot From
This register determines which configuration space (factory, user#1 or user
#2) should be loaded into the camera following a power cycle or reset
(
‘SW_Reset’
) command. Upon a power cycle or reset, the camera reads the