Page 1: ...RS 0800 LVD Installation and User Guide Part No 34981 02A Issue 2 0 January 15 2004...

Page 2: ...t all information in this document is accurate the Authors accept no liability for any errors that may arise No part of this document may be transmitted or copied in any form or by any means for any p...

Page 3: ...Product 2 1 2 1 Enclosure Chassis 2 1 2 2 Status Indicator LEDs 3 1 3 The Plug in Modules 4 1 3 1 Power Supply Module 4 1 3 2 Cooling Modules 5 1 3 3 Input Output Module 6 1 3 4 Drive Carrier Modules...

Page 4: ...7 4 Interface Cable Attachment 24 2 8 Drive Carrier Configuration 25 2 8 1 Planning and Configuring Your Installation 25 2 9 Drive Carrier Installation 25 2 9 1 Parts Check List 25 2 9 2 Procedure 26...

Page 5: ...ith Hardware Faults 36 4 6 Continuous Operation During Replacement 37 4 7 Replacing a Module 37 4 7 1 Power Supply Module 37 4 7 2 Cooling Module 39 4 7 3 I O Modules 40 4 7 4 Drive Carrier Module 42...

Page 6: ...vi RS 0800 LVD User Guide...

Page 7: ...ts are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency e...

Page 8: ...without all units in place Permanently unplug the unit if you think that it has become damaged in any way and before you move it Drive Carrier Module Caution Label Do not operate with modules missing...

Page 9: ...vided to the power cord Check the grounding of the enclosure before applying power Provide a suitable power source with electrical overload protection to meet the requirements laid down in the technic...

Page 10: ...e used when addressing these concerns The electrical distribution system must provide a reliable earth for each unit and the rack Each power supply in each unit has an earth leakage current of 0 8mA T...

Page 11: ...ate the warranty If you remove any drive module you may lose data If you remove a drive module replace it immediately If it is faulty replace it with a drive module of the same type and capacity Ensur...

Page 12: ...and installation information and editorial enhancements Preface Safety information revised and illustrations of various safety labels included Chapter 1 New illustrations of PSU Cooling and I O modul...

Page 13: ...hapter 1 Introduction 1 1 RS 0800 LVD Storage System This manual provides information to assist in the installation and maintenance of an RS 0800 LVD Two Channel enclosure subsystem Figure 1 1 The RS...

Page 14: ...on 1 2 1 Enclosure Chassis The chassis consists of a sheet metal enclosure assembly containing a Backplane PCB and module runner system The chassis assembly contains 8 drive bays at the front each of...

Page 15: ...lements of the Enclosure Each element Power Cooling Device status is interfaced to the processor 1 2 2 1 Ops Panel Indicators The Operator Panel includes Light Emitting Diode LED indicators which show...

Page 16: ...the subsystem core product Figure 1 7 LED Indicator Symbol Meaning System Status Green to signify that there is power applied to the enclosure Amber if the ESI processor has failed Power Status Green...

Page 17: ...upply while you replace the faulty unit Important Module replacement should only take a few minutes to perform but must be completed within 10 minutes from removal of the failed module Alternatively i...

Page 18: ...for the 2 x 4 configuration and one will be used in the 1 x 8 configuration 1 x 8 Ultra 320 SCSI Loopback module Figure 1 11 with no external connectors This will be used in conjunction with a 2 x 4 I...

Page 19: ...Introduction 7 Figure 1 10Ultra 320 SCSI IO Module Figure 1 11 Ultra 320 SCSI Loopback Module...

Page 20: ...RS 0800 LVD User Guide 8 Figure 1 12Ultra 160 SCSI Loopback Module Figure 1 13 RS 0800 LVD Enclosure with Ultra 320 SCSI I O Module Installed...

Page 21: ...ion protection and affords the drive maximum physical protection The front cap also supports an ergonomic handle which provides the following functions Camming of carrier into and out of drive bays Po...

Page 22: ...n airflow and ensure correct operation blank modules are available for Cooling module blank Power Supply module blank Warning Operation of the Enclosure with ANY modules missing will disrupt the airfl...

Page 23: ...mm Depth 545mm Maximum Configuration Rack mount 22 kg Empty Enclosure Rack 6 5 kg Power Supply Module 1 75 kg Cooling module 1kg I O module 1 25kg Voltage 100 120 or 200 240 VAC Autoranging Frequency...

Page 24: ...ting 305 to 12 192 m 1000 to 40 000 ft Operational Shock Vertical axis 5g peak 1 2 sine 10ms Operational Vibration Random vibration power spectrum available on request Non Operational Shock 20g 20ms s...

Page 25: ...2 channels linking them to form a single channel of 8 drives Mounting Rear Single Bay Rear Single Bay Connectors 2 x VHDCI 0 8mm Very High Density Connectors None Termination None None Current Limit 1...

Page 26: ...RS 0800 LVD User Guide 14...

Page 27: ...l plug in modules are shown in Figure 2 1 Please refer to Section 2 6 for details of Ultra 320 SCSI configurations and installation Table 2 1 RS 0800 LVD Configuration Module Location Drive Bays ALL d...

Page 28: ...4 bays wide by 2 bays high It also has 3 x 2 module bays at the rear The front bays are numbered 1 to 4 from left to right viewed Loopback module If a loopback module is used it must only be fitted in...

Page 29: ...en handling RS 0800 LVD modules and components Avoid contact with Backplane components and module connectors etc 2 3 1 Pre Requisites The RS 0800 LVD enclosure is designed for installation into an ind...

Page 30: ...led but excluding all plug in modules Rack mount front flange mounting screws 4 off 2 3 3 2 Procedure 1 Check for damage 2 Slide the chassis assembly onto the rack rails until the front flanges engage...

Page 31: ...specially to the rear connector on the supply Warning Handle the module carefully and avoid damaging the connector pins Do not install the module if any pins appear to be bent 2 Loosen the screws secu...

Page 32: ...the cooling module to be installed until they are clear of the sides of the cooling module 2 Slide the cooling module fully into the enclosure A slight resistance will be felt as the connector pushes...

Page 33: ...s of 4 drives each device bay accepts a 3 5 Ultra 320 compatible disk drive with 80 pin SCA 2 connector with burst data transfer speeds of 320MB s Each channel is routed from one of the VHDCI 0 8mm pi...

Page 34: ...switch In a 2 x 4 Configuration the range defined by the right I O module will control the IDs of the right 4 drives and the left I O will control the IDs of the left 4 drives i e Left I O 1 1 1 2 2...

Page 35: ...u have received the correct IO Module variant Please refer to Section 1 5 7 Ultra 320 SCSI I O Module Specification for details 2 7 2 Drive Address Ranges Use the Range switch on the rear of the I O m...

Page 36: ...ng that 2 x 4 I O module switch settings are appropriate for the configuration required 2 7 4 Interface Cable Attachment 2 7 4 1 Termination External Ultra 320 compatible termination is required Impor...

Page 37: ...nfiguration requirements of your RS 0800 LVD system Please refer to Section 2 2 for information on your overall system configurations When planning your system configuration please remember that All R...

Page 38: ...the left 2 Slide the carrier gently all the way into the enclosure until it is stopped by the camming lever on the right of the carrier Figure 2 11 3 Cam the carrier home the camming foot on the base...

Page 39: ...27 Note Removal is the reverse of this procedure press on the latch to release the handle Figure 2 11 Installing an Ultra 320 SCSI Drive Carrier Module 2 Figure 2 12Installing an Ultra 320 SCSI Drive...

Page 40: ...Rotate the key in a clockwise direction until the indicator is visible in the aperture beside the key 4 Remove the key De activation is the reverse of this procedure that is Rotate the key in a anti...

Page 41: ...s to ensure that a safe grounding system is provided If a rack distribution system is being used Ensure power is removed from the rack Connect the supplied power cord to the rack distribution and the...

Page 42: ...RS 0800 LVD User Guide 30...

Page 43: ...e below to power up the enclosure 1 Apply AC Mains power to the enclosure Turn the Power Supply modules to ON 2 All LEDs on the ESI Ops Panel should be lit Green when the enclosure power is activated...

Page 44: ...er Green and lower Amber In normal operation the Green LED will be ON and will flicker as the drive operates 3 5 Power Down To power the enclosure down either Switch OFF the Power Supply modules insta...

Page 45: ...in that table 4 1 1 Initial Start up Problems 4 1 1 1 Faulty Cords First check that you have wired up the subsystem correctly Then if cords are missing or damaged plugs are incorrect cords are too sho...

Page 46: ...ber LEDs indicate there is a critical fault present within the module 4 2 2 ESI Ops Pane LEDs The ESI Ops Panel displays the aggregated status of all the modules The ESI Ops Panel LEDs are shown in Fi...

Page 47: ...path 1 Check for other Amber LED indications on the Power Supply modules If there is a PSU error present there may be a communications problem with that Power Supply module Remove and then re fit the...

Page 48: ...losure can overheat causing power failure and data loss Such use will invalidate the warranty Replace a faulty drive with a drive of the same type and capacity All drive bays must be fitted with eithe...

Page 49: ...and are not operator removable these modules must only be removed by trained maintenance technicians who are aware of the hazards associated with the PSUs Power must not be applied to the PSU when it...

Page 50: ...RS 0800 LVD User Guide 38 5 Grip the handle on the Power Supply front panel lift the latch up and withdraw the Power Supply module Figure 4 2 Removing a PSU Module 1 Figure 4 3 Removing a PSU Module 2...

Page 51: ...andle lift the latch on the front of the Power Supply module and slide the module into the enclosure The latch engages automatically 4 Return the retaining bracket to the centre position and tighten t...

Page 52: ...he tray will be flush with the rear members of the enclosure 3 Return the retaining brackets to the centre position and tighten the securing screws 4 7 3 I O Modules Please refer to section 2 7 for fu...

Page 53: ...Troubleshooting 41 2 Slide the I O module out of the enclosure see Figure 4 7 Figure 4 6 Removing an I O Module 1 Figure 4 7 Removing an I O Module 2...

Page 54: ...ossible we recommend that you perform All steps of the following procedure to ensure that the drive has stopped prior to removal 1 Release the carrier handle by pressing the latch in the handle toward...

Page 55: ...s or characters 64K indicates 65 536 bytes or characters Cable Throughout this RS 0800 LVD user guide this term is used in accordance with the preferred US context of an insulated flexible electric wi...

Page 56: ...characters using parallel electrical paths for each bit of the character for example 8 paths for 8 bit characters Data is stored in computers in parallel form but may be converted to serial form for...

Page 57: ...y carrier module 10 25 28 e Enclosure 2 4 10 15 17 36 ESD 17 37 ESI processor 35 ESI Ops Panel 3 29 31 33 ESI Ops Panel LEDs 33 g grounding 29 i I O connectors 24 I O module 2 6 15 34 40 Input Output...

Page 58: ...RS 0800 LVD User Guide 46...