Chapter 3 Environment description and installation
3-15
3.4 Specification
3.4.1 Product individual specification
400V model
EDX-
□□□
-43 (-E)
iDrive
075 150 220
Horsepower (HP)
1 2 3
Suitable motor capacity (kW)
0.75 1.50 2.2
Rated output current (A
RMS
)
2.3 3.8 5.2
Rated capacity (kVA)
1.7 2.9 4.0
Input voltage range
(
V
)
3-phase 380~480V+10%, -15% (50/60Hz)
Output voltage range
(
V
)
3-phase 0~480V
Input current (A
RMS
)
3.0 4.8 6.6
Net weight (Kg)
1.68
1.70 1.73
Allowable momentary power
loss time (S)
1.0 2.0 2.0
Enclosure
IP20
100V model
200V model
EDX-
□□□
-11
EDX-
□□□
-21 (-E)
EDX-
□□□
-23
iDrive
020
040
075 020 040 075 150 220 020 040 075 150 220
Horsepower (HP)
0.25
0.5
1
0.25 0.5
1 2 3 0.25 0.5
1
2
3
Suitable motor capacity (kW) 0.2
0.4
0.75 0.2 0.4 0.75 1.5 2.2 0.2 0.4 0.75 1.50 2.2
Rated output current (A
RMS
)
1.7
3.1
4.2
1.7 3.1 4.2 7.5 10.5 1.7 3.1
4.2
7.5 10.5
Rated capacity (kVA)
0.53 0.88 1.60 0.53 0.88 1.60 2.90 4.00 0.53 0.88 1.60 2.90 4.00
Input voltage range
(
V
)
1-phase
100~120V+10%,
-15% (50/60Hz)
1-phase
200~240V+10%,
-15% (50/60Hz)
3-phase
200~240V+10%,
-15% (50/60Hz)
Output voltage range
(
V
)
3-phase 0~240V
Input current (A
RMS
)
7.1
12.2
17.9
4.3 5.4 10.4 15.5 21
3.0 4.0
6.4
9.4 12.2
Net weight (Kg)
0.62 0.68 0.72 0.71 0.73 0.73 1.25 1.3 0.61 0.61 0.66 0.95
1
Allowable momentary power
loss time (S)
1.0
1.0
1.0 1.0 1.0 1.0 2.0 2.0 1.0 1.0 1.0
2.0 2.0
Enclosure IP20
Non-Standard Models