Chapter 4 Software index
4-11
A07 = 001 ~ 006 User selectable fixed V/F patterns (refer to following table).
E.U.
Spec.
A07 V/F
Pattern
U.S.
CAN
Spec.
A07
V/F Pattern
General
001
General
004
Hi
gh start torque
002
Hi
gh start torque
005
50 Hz Motors
Variable torque
003
60 Hz Motors
Variable torque
006