Chapter 4 Software index
4-5
b40
Terminal S6 Function
009
b41
Terminal AIN Function
016: PID Disabled
017: Analog Frequency Signal
Input Terminal AIN
018: PID feedback signal (AIN)
019: DC Brake (ON command)
017
b42
Frequency UP/DOWN Control (MFIT)
000:
UP/DOWN Control ON
(Freq. Held at Power OFF)
001:
UP/DOWN Control ON
(Freq. Reset to 0Hz at OFF)
002:
UP/DOWN Control ON
(As 000 – UP/DOWN is
Available when Output OFF)
000
b43
S1 ~ S6 Digital Input Scan Time
001 ~ 100 (mS x 8)
010
b44
Jog Frequency
00.0 ~ 200 (Hz)
05.0
*1
b45
Preset Frequency 1
00.0 ~ 200 (Hz)
05.0
*1
b46
Preset Frequency 2
00.0 ~ 200 (Hz)
05.0
*1
b47
Preset Frequency 3
00.0 ~ 200 (Hz)
10.0
*1
b48
Preset Frequency 4
00.0 ~ 200 (Hz)
20.0
*1
b49
Preset Frequency 5
00.0 ~ 200 (Hz)
30.0
*1
b50
Preset Frequency 6
00.0 ~ 200 (Hz)
40.0
*1
b51
Preset Frequency 7
00.0 ~ 200 (Hz)
50.0
*1
b52
Preset Frequency 8
00.0 ~ 200 (Hz)
60.0
*1
b53
0-10V Analogue Output Select
000: Output Frequency
001: Set Frequency
002: Output Voltage
003: DC Voltage
004: Output Current
005: PID feedback Signal
000 *1
b54
Analogue Output Gain
00.0 ~ 200 (%)
100
*1
b55
Multi-Function Output Relay RY1
000: RUN
001: Frequency Reached
(± b57)
002: Frequency in Range
(b56 ± b57)
003: Frequency Detected
(>b56)
004: Frequency Detected
(<b56)
005: Fault
006: Auto Reset / Restart
007: Momentary Power Loss
008: Emergency Stop (E.S.)
009: Base Block (b.b.)
010: Motor Overload
011: Inverter Overload
012: xxx Not Used xxx
013: Power ON
014: Communication Error
015: Output Current (>b58)
000
b56
Output Frequency Reached Set Value
00.0 ~ 200 (Hz)
00.0
*1
b57
Frequency Detection Range
00.0 ~ 30.0 (±Hz)
00.0
*1