1.4  REMOTE CONTROLS AND ROOM 

CHRONOTHERMOSTATS  

(OPTIONAL).

The boiler is prepared for application of room 

chronothermostats and external probe. These 

Immergas components are available as separate 

kits to the boiler and are supplied on request.

All Immergas chronothermostats are connected 

with 2 wires only. Carefully read the user and 

assembly instructions contained in the accessory

kit.

• On/Off digital chronothermostat. The 

chronothermostat allows:

  - to set two room temperature values: one for 

day (comfort temperature) and one for night 

(lower temperature);

  - to set up to four on/off differential weekly 

programs;

  -  selecting the required function mode from 

the various possible alternatives.

• permanent functioning in comfort temp.

• permanent operation in lower temp.

• permanent function in adjustable anti-freeze 

temp.

  The chronothermostat is powered by two 1.5V 

LR 6 type alkaline batteries;

•  There are two types of Remote Friend Control

V2

 

(CAR

V2

) (Fig. 1-3) and Digital Remote 

Control (CRD) (Fig. 1-4) both with room 

chronothermostat functioning. In addition to 

the functions described in the previous point, 

the Remote Friend Control

V2

 enables the 

user to control all the important information 

regarding operation of the appliance and the 

heating system with the opportunity of easily 

intervening on the previously set parameters 

without having to go to the place where the 

appliance is installed. The Remote Friend 

Control

V2

 panel is provided with self-diagnosis 

to display any boiler functioning anomalies. 

The climate chronothermostat incorporated in 

the remote panel enables the system delivery 

temperature to be adjusted to the actual needs 

of the room being heated, in order to obtain 

the desired room temperature with extreme 

precision and therefore with evident saving 

in running costs. The chronothermostat is fed 

directly by the boiler by means of the same 2 

wires used for the transmission of data between 

boiler and chronothermostat.

Important:

 If the system is subdivided into zones 

using the relevant kit. the CAR

V2

 must be used 

with its climate thermostat function disabled, i.e. 

it must be set to On/Off mode. The CRD cannot 

be used for plants divided into zones.

Electrical connection of the Remote Friend 

Control

V2

 or chronothermostat On/Off 

(Optional)

The operations described below must 

be performed after having removed the voltage 

from the appliance.

 The eventual thermostat 

or On/Off room chronothermostat must be 

connected to terminals 40 and 41 eliminating 

jumper X40 (Fig. 3-2). Make sure that the On/

Off thermostat contact is of the “clean” type, i.e. 

independent of the mains supply, otherwise the 

electronic adjustment card would be damaged. 

The eventual Remote Friend Control

V2

 must 

be connected by means of terminals IN+ and 

IN- to terminals 42 and 43, eliminating jumper 

X40 on the terminal board (in the boiler) 

respecting polarity (Fig. 3-2). Connection with 

the wrong polarity prevents functioning, but 

without damaging the Remote Friend Control

V2

The boiler works with the parameters set on 

the Remote Friend Control

V2

 only if the boiler 

main selector is turned to Domestic/Remote 

Friend Control

V2

 (

). The boiler can only 

be connected to one remote control.

Important:

 If the Remote Friend Control

V2

Digital Remote Control or any other On/Off 

chronothermostat is used arrange two separate 

lines in compliance with current regulations 

regarding electrical systems. Boiler pipes must 

never be used to earth the electric or telephone 

lines. Ensure elimination of this risk before 

making the boiler electrical connections.

1.5  EXTERNAL PROBE (OPTIONAL).

• External temperature probe (Fig. 1-5). This 

sensor can be connected directly to the boiler 

electrical system and allows the max. system 

delivery temperature to be automatically 

decreased when the outside temperature 

increases, in order to adjust the heat supplied 

to the system according to the change in 

external temperature. The external probe 

always operates when connected, regardless of 

the presence or type of room chronothermostat 

used and can work in combination with the On/

Off chronothermostat and the CAR

V2

, (it cannot 

be connected to the CRD). The correlation 

between system delivery temperature and 

outside temperature is determined by the 

position of the knob on the boiler control 

panel according to the curves shown in the 

diagram (Fig. 1-6). The external probe electrical 

connection must be made on clamps 38 and 39 

on the boiler circuit board (Fig. 3-2).

*

 (Fig. 1-6) Position of the heating temperature 

user adjustment.

Summary of Contents for ZEUS 24 Superior

Page 1: ...ZEUS 24 28 kW IE Instruction booklet and warning 1 038761ENG...

Page 2: ...ct correctly Maintenance must be carried out by skilled technical staff The Immergas Authorised After sales Service represents a guarantee of qualifications and professionalism The appliance must only...

Page 3: ...sure sufficient space for normal servicing therefore it is advisable to leave a clearance of at least 3 cm between the boiler casing and the vertical sides of the cabinet Leave adequate space above th...

Page 4: ...ranty before making the boiler connections carefully clean the heating system pipes radiators etc with special pickling or de scaling products to remove any deposits that could compromise correct boil...

Page 5: ...t function disabled i e it must be set to On Off mode The CRD cannot be used for plants divided into zones Electrical connection of the Remote Friend ControlV2 or chronothermostat On Off Optional The...

Page 6: ...s Cut the seal in the relative groove at the desired diameter 80 run it along the bend and fix it using the sheet steel plate Insert the exhaust pipe with the male end smooth into the female side of t...

Page 7: ...the boiler the fumes separator positioned on the air fumes extraction well must be adjusted Fig 1 12 Adjustment is carried out by loosening the front retainer screw and moving the indicator to the cor...

Page 8: ...Exhaust m 2 0 Terminal complete with concentric hori zontal intake exhaust 80 125 Intake and Exhaust 33 m 2 0 m 5 5 Intake m 14 3 Exhaust m 11 0 Terminal complete with concentric horizontal intake exh...

Page 9: ...t kits 80 125 Kit assembly Fig 1 18 install the bend with flange 2 on the central hole of theboiler inserting the seal 1 and tighten using the screws in the kit Fit the male end smooth of the adapter...

Page 10: ...flues and air intake pipes according to the diagram shown in the figure Fig 1 22 Fumes are expelled from duct S Air is taken in through duct A for combustion Intake duct A can be installed either on...

Page 11: ...red use 80 pipes with insulation see insulated separator kit 80 80 chapter Insulated separator kit 80 80 Kit assembly Fig 1 26 install flange 4 on the central hole of the boiler fitting seal 1 and tig...

Page 12: ...kit optional air intake takes place directly from the environment in which the boiler is installed and the fumes are expelled in an individual flue or directly to the outside The boiler in this config...

Page 13: ...tail to ensure maximum reliability Thelowerinspectionflangeensurespracticalcontrol oftheboilerandthecoiledheatexchangerandeasy internal cleaning The domestic water attachments are found on the flange...

Page 14: ...irculation pump 9 Gas valve 10 3 way valve motorised 11 System filler tap 12 System expansion tank 13 Domestic hot water probe 1 17 ZEUS 24 28 KW BOILER COMPONENTS 14 Stainless Steel Boiler 15 3 bar s...

Page 15: ...devices for flue extraction and relative accessories switch off the appliance and on completion of operations ensure that a qualified technician checks efficiency of the ducting or other devices Neve...

Page 16: ...it and that the system is free of air deaerated circulating pump blocked free the circulating pump If this phenomenon occurs frequently contact a qualified technician for assistance e g Immergas Techn...

Page 17: ...elow 4 C and stops once it exceeds 42 C The antifreeze function is guaranteed if the boiler is fully operative and not in block status and is electrically powered To avoid keeping the system switched...

Page 18: ...nd or exhaust terminals are not blocked check activation of the no air safety pressure switch ensure activation of all adjustment devices seal the gas flow rate regulation devices if settings are modi...

Page 19: ...ESHOOTING N B Maintenance must be carried out by a qualified technician e g Immergas Technical Assistance Service Smell of gas Caused by leakage from gas circuit pipelines Check sealing efficiency of...

Page 20: ...f gas by turning in a clockwise direction the heating potential increases and in an anti clockwise direction it decreases Adjust the boiler minimum thermal input Fig 3 3 N B only proceed after having...

Page 21: ...seconds LED 7 650 seconds Standard setting LED 8 Heating switch on delay request from Room thermostat and Remote Friend ControlV2 The boiler is set to switch on immediately after a request In the cas...

Page 22: ...n the casing Unhook the lower part of the casing as described in the figure Pull the casing 4 forwards and up at the same time see figure to detachit from the upper hooks 3 15 YEARLY APPLIANCE CHECK A...

Page 23: ...erted in the test pressure outlet of the modulating adjustable gas valve and on the sealed chamber positive pressure test outlet The power data given in the table is obtained with intake exhaust pipe...

Page 24: ...ppm 123 71 161 84 165 80 Flue temperature at nominal heat output C 108 109 107 Flue temperature at minimum heat output C 87 91 91 Zeus 28 kW Gas nozzle diameter mm 1 35 0 79 0 79 Supply pressure mbar...

Page 25: ...loss at case with burner On Off 0 40 0 89 0 60 0 62 Heat loss at flue with burner On Off 5 50 0 03 5 50 0 01 Heating circuit max working pressure bar 3 3 Heating circuit max working temperature C 90...

Page 26: ......

Page 27: ......

Page 28: ...mmergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038761ENG rev ST 002107 000 10...

Reviews: