39
Menù Heat pump -> State
Integration status
Indicates the operating mode of the part of integration
-1 = integration disabled
0 = Off
1 = Integration on
2 = Integration on
3 = Integration on during defrost-
ing
4 = Integration on for heat pump
anomaly
5 = Integration on for low external
temperature
12 = Integration off for DHW
request
13 = Capacity Limit
50 = Integration not allowed
51 = No CH request
100 = Integration anomaly
DHW status
Indicates the operating mode during DHW request
-1 = DHW disabled
0 = DHW enabled
1 = DHW not active (request for
central heating or cooling)
2 = Three-way DHW drive
100 = DHW anomaly
Flow switch
Indicates circulation inside the hydraulic circulator
On/off
Input status ON/OFF
Indicates the input state for the on/off control
On/Off
DHW Request
Indicates the presence of a heat request by the DHW storage
On/Off
Input status Reducing Indicates the input state for the reduction control
On/Off
Fault (Current alarm
code)
Current anomaly code
Fault inverter
Inverter anomaly code
Menù Heat pump -> Auxiliary info
Menu item
Description
Range
Overheating temp.
Indicates the overheated gas temperature
Overheating target
temp.
Indicates the overheated gas required temperature
Inverter Temp.
Indicates the inverter temperature
Max freq. compressor Indicates the maximum frequency that can be reached by the compressor with the
present conditions
Requested frequency
Indicates the frequency requested from the compressor
Fan speed Top
Indicates the upper fan speed
Fan speed Low
Indicates the lower fan speed
Circulator speed
Indicates the pump speed
Water control point
Temperature control set
Water temp. control
Reference probe for the temperature control set
Menù Service -> Test maximum press.
Menu item
Description
Range