background image

InstallatIon and 

operatIng InstructIons

the Kalla

 heater

12/2017

Summary of Contents for Kalla 6.6

Page 1: ...Installation and Operating Instructions The Kalla heater 12 2017 ...

Page 2: ...n using the heater 7 First heating 7 Sauna room 7 Temperature control 7 Heating time 7 Water thrown on heater 7 Sauna room structure 8 7 Wall mount installation 9 8 Installation instructions 10 Installation of external control and sensor 11 9 Wiring diagram 12 Controller card wiring heater 12 Controller card wiring controller 12 10 Heater control and operation 13 First time use of the heater calib...

Page 3: ...able for use in a family sauna one 1 heater per sauna room Retain the installation and operating instructions for further reference Always check the adequacy of the fire protection distances Failure to observe the wiring instructions may result in a risk of fire Always check the sauna room before switching the heater on Always check that the controller has switched the heater off after the set tim...

Page 4: ...er visually If you notice any discrepancies please contact the store where you purchased the heater or e mail info mondex fi 3 The heater is installed so that it leans against a wall using the bracket provided see the dimensions on page 9 4 To facilitate installation adjust the heater s feet so that they extend out 8 9 cm 2 Kalla heater 3 Heater assembly and installation Kalla heater ...

Page 5: ...ng the stones in this way until all of them have been placed Note Ensure that the resistors do not touch the heater s net frame anywhere There must always be a stone between a resistor and the frame Note Do not remove the bands around the resistors If there are two bands one of them is located at approximately 20 cm from the bottom and another at approximately 10 15 from the top They keep the resi...

Page 6: ...00 V 3N Connecting cable 5 x 1 5 mm 5 x 2 5 mm Fuse 3 x 10 A 3 x 16 A 4 Technical specifications Table 4 1 Type A B C D Volume Kalla 6 6 100 850 100 1900 6 9 m Kalla 9 0 120 870 100 1900 8 15 m Type Width Depth Height Kalla 6 6 350 304 1030 Kalla 9 0 350 304 1030 Type Stone amount kg Kalla 6 6 80 Kalla 9 0 80 Table 4 3 Table 4 2 Table 4 4 Minimum distances to inflammable material mm D C C A B ...

Page 7: ...una room before switching the heater on Always make sure that the timer has switched the power off after the set time period Temperature control The temperature is adjusted from the control panel see page 14 The actual heating time depends on the dimensions structure and thermal insulation of the sauna The temperature in the sauna room can be maintained at the desired level with the thermostat If ...

Page 8: ...nd on timber surfaces by 1 5 m3 The factor for glass surfaces glass walls doors and uninsulated stone surfaces is also 1 2 m3 per square metre In borderline cases you should choose a heater with higher power The sauna needs efficient ventilation for a good oxygen level and a sufficient amount of fresh air The air in the sauna needs to change at least 6 times per hour For a sauna with an electric h...

Page 9: ...e adhered to the recommended safety distances between the heater and any inflammable materials on the sides and underneath the heater are met Floor Keep in mind that the adjustable feet may add to the total height of the heater 7 Wall mount installation 130 150 810 401 5 327 5 51 ...

Page 10: ...ion and Operating Instructions Kalla 8 Installation instructions Supply cable 5 x 1 5 mm2 5 x 2 5 mm2 Sensor Switch board Controller Sauna Changing room Utility room Controller ca 250 mm ca 250 mm Sensor max 99 cm ...

Page 11: ... drop of silicone adhesive The length of the sensor cable is 6 m Cut the excess wire and connect the other end to the heater Ensure that a minimum of 7 mm of the end of the wire is stripped to ensure a proper contact The wall mounting plate is either mounted to the wall using three screws or affixed to the bottom of the mounting box The mounting plate is covered first with a cover plate and finall...

Page 12: ...lla 9 Wiring diagram Quick connector Controller card wiring heater Controller card wiring controller To the controller To the overheating protector To the temperature sensor White Grey Green Blue Red White White Black Black OVERHEATING PROTECTION ...

Page 13: ...n the upper left hand corner When 2 hours have elapsed or the blue LED light at the lower right The heater is operated by adjusting its operating time and temperature and then by switching the heater on from the power switch Overheating protector The overheating protector reset button is located above the heater s main power switch under a protective cap Twist the cap to open The red reset button ...

Page 14: ...is switched on again If necessary contact the dealer or manufacturer Warnings Due to a risk of fire do not use the sauna to dry clothes or laundry Exercise caution with a hot heater since the heater stones and metal parts become very hot and can cause burns The water steam rising from the heater is hot and can cause burns Children disabled and ill persons who are using the sauna should be supervis...

Page 15: ...and spare parts In case of a fault that cannot be solved please contact the store where you purchased the heater or email info mondex fi Spare parts can be purchased from Mondex distributors and the manufacturer When purchasing spare parts please refer to the name power serial number and manufacturing date of the heater to ensure you receive the correct parts Natural stone as material Small pebble...

Page 16: ...l support info mondex fi Premec Oy Kettukallionkatu 4 84100 Ylivieska Finland info mondex fi www mondex fi Heater maintenance history We recommend changing the heater stones at one year intervals Date Procedure ...

Reviews: