background image

FWXV10AATV3(R)

FWXV15AATV3(R)

FWXV20AATV3(R)

FWXM10AATV3(R)

FWXM15AATV3(R)

FWXM20AATV3(R) 

INSTALLATION MANUAL

Daikin Altherma

Heat pump convector

Summary of Contents for Altherma FWXV10AATV3

Page 1: ...FWXV10AATV3 R FWXV15AATV3 R FWXV20AATV3 R FWXM10AATV3 R FWXM15AATV3 R FWXM20AATV3 R INSTALLATION MANUAL Daikin Altherma Heat pump convector...

Page 2: ...of the machine in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I Installer Refers to pages containing instructions or information for the...

Page 3: ...nal components 8 2 5 Removing the side panels 9 2 6 Vertical installation 9 2 7 Horizontal or ceiling installation 10 2 8 Hydraulic connections 10 2 9 Condensation discharge 11 2 10 Filling the system...

Page 4: ...e direct air flow Do not leave the room closed for long periods Periodically open the windows to ensure a correct change of air This instruction leaflet is an integral part of the appliance and conseq...

Page 5: ...ng materials which could become a source of danger It is forbidden to climb onto the appliance or rest any object on it The external parts of the appliance can reach temperatures of more than 70 C Pro...

Page 6: ...U M FWXV10AATV3 R FWXV15AATV3 R FWXV20AATV3 R A mm 999 1199 1399 U M FWXM10AATV3 R FWXM15AATV3 R FWXM20AATV3 R A mm 578 778 978 A FWXV FWXM 135 mm 601 mm A GENERAL Dimensions Overall dimensions 2 pipe...

Page 7: ...he discharge of the condensation outside in case of ceiling installation FWXM series the airflow is not directed towards persons The following descriptions of the various mounting phases and the relat...

Page 8: ...chine follow the procedures below Remove the upper grill loosen the fixing screws of the upper grill remove the grill Remove the front grill extract the grill until it is completely out of the seat ti...

Page 9: ...he brackets can be adjusted with a spirit level Install the unit at level with a possible 1 2 tolerance towards the drainage pipe to facilitate the flow of water Fully tighten the four screws to block...

Page 10: ...kage Wall plugs Brackets Screws Drainage pipe Hydraulic connections NB the nominal diameter unless otherwise indicated always refers to the internal diameter To avoid the formation of surface condensa...

Page 11: ...tainer it must be open to the atmosphere and the tube must not be immersed in water to avoid problems of adhesiveness and counter pressure that would interfere with the normal outflow If there is a he...

Page 12: ...he same collection bowl insulate the bowl condensation discharge pipe along all of its length Breather Filling the system Evacuating air while filling the system When starting up the system make sure...

Page 13: ...tegory III Maintenance Cleaning the outside Routine maintenance is indispensable to keep the heat pump convector in perfect working condition safe and reliable over the years This can be done every si...

Page 14: ...the seat tilt the grill and slide it outwards then remove the filter by pulling it outwards Extraction of filter cells After a period of continuous operation and in consideration of the concentration...

Page 15: ...fan with the mobile panel missing or out of position After finishing the cleaning of the filter check that the panel is mounted correctly Cleaning filtering seats For the versions with a grill with fl...

Page 16: ...t activate even if there is hot or cold water in the hydraulic circuit The hydraulic valve remains closed Dismount the valve body and check if the water circulation is restored Check the working effic...

Page 17: ...drainage pipe The condensation discharge does not need an inclination for correct drainage The connection pipes and the valve unit are not insulated well Check the insulation of the pipes The applian...

Page 18: ...18 S I U...

Page 19: ...19 S I U EN...

Page 20: ...Copyright 2019 Daikin cod N420249A 03...

Reviews: