35
3.10 PROGRAMMING.
The water heater is set up for possible programming
of several operation parameters. By modifying these
parameters as described below, the system can be
adapted according to specific needs.
Menù Service
Menu item
Description
Range
Definition of zone
Zone system sub-menu settings
-
Defining plant
Sub-menu to define the devices connected to the system
-
Device configuration
Sub-menu to set the device's configuration
-
Thermoreg. heat.
Central heating thermoregulation setting sub-menu
-
Thermoreg. cool
Cooling thermoregulation setting sub-menu
-
Thermoreg. parameters Parameters thermoregulation setting sub-menu
-
Integration
System integration setting sub-menu
-
Heat pump
Heat pump operating parameters sub-menu
-
Manual
Manual operating parameters sub-menu
-
Factory settings
Default settings restore sub-menu
-
Menù Service -> Definition of Zone
Menu item
Description
Range
Default
Customised
value
Room Control Interface
Enable operation of the supplied remote control if set on “R. Panel”.
If “TA” set, the central heating and cooling requests will be made based
on the request of an external thermostat.
Remote
Panel/T.A.
R.Panel
Enable dew point
Enable operation with a humidity probe in the remote panel.
Yes / No
No
Menù Service -> Defining plant
Menu item
Description
Range
Default
Customised
value
External probe
Enables operation with the external probe.
No / PdC
No
Enable DHW
operation in domestic circuit
Yes / No
No
Reduction function
Enable PdC operation frequency reduction, which is controlled by the
said terminal board.
Yes / No
No
Power
Power percentage in reduction mode.
50% ÷ 100%
75%
Circulator control
Enable the pump operation with speed set “Max.speeed” or the
modulating mode with tracking of the “Modulating” temperature
differential.
Max.speed/
Modulating
Modulating
Speed min
Value of minimum speed used in modulating operation.
19% ÷ 50%
50%
Speed max
Value of maximum speed used in modulating operation.
50% ÷ 100%
100%
Delta T
Temperature delta to be maintained with modulating operation.
2 ÷ 20
5
Menù Service -> Device configuration
Menu item
Description
Range
Default
Customised
value
H.P. control
Setting “Yes”, the default remote control supplied manages the heat
pump.
Setting “No”, the remote control does not control the heat pump and
must be coupled with other Immergas systems (System Manager). If
“No” is set, it displays another item “slave address”.
N.B.:
if it is erroneously set to “No”, it is still possible to change the
selection.
Yes / No
Yes
Slave address
Address to configure according to the zone where the device is in-
stalled (e.g.: zone 1 = 41, zone 2 = 42, zone 3 = 43, etc...).
1 ÷ 247
21
Assistance Menu -> Central Heating thermoregulation
Menu item
Description
Range
Default
Customised
value
Access the “Service” menu by pressing the right
“Menu” button and turning the main switch until
selecting the desired menu. Press the main switch
to confirm the selection. Insert the relative access
code and customise the parameters according to
your requirements.