Low temperature table (30/35) hotter zones
Model:
Audax TOP 18 ErP
Air/water heat pump: yes
Water/water heat pump: no
Brine/water heat pump: no
Low temperature heat pump: no
With additional central heating device: no
Mixed central heating device with heat pump: no
The parameters are declared for average temperature application, except for low temperature heat pumps. The parameters for low temperature heat
pumps are declared for low temperature application
The parameters are declared for hotter climatic conditions.
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
Nominal
output
14.67
kW
Room central heating sea-
sonal energy efficiency
η
s
225
%
Central heating capacity declared with a partial load and indoor
temperature equivalent to 20°C and outdoor temperature Tj
Performance coefficient declared with indoor temperature equivalent
to 20°C and outdoor temperature TJ
T
j
= – 7 °C
Pdh
kW
T
j
= – 7 °C
COPd
–
T
j
= + 2 °C
Pdh
14.67
kW
T
j
= + 2 °C
COPd
2.82
–
T
j
= + 7 °C
Pdh
9.43
kW
T
j
= + 7 °C
COPd
3.96
–
T
j
= + 12 °C
Pdh
3.88
kW
T
j
= + 12 °C
COPd
9.46
–
T
j
= bivalent temperature
Pdh
14.67
kW
T
j
= bivalent temperature
COPd
2.82
–
T
j
= temperature operating
limit
Pdh
14.67
kW
T
j
= temperature operating
limit
COPd
2.82
–
for air/water heat pumps: Tj
= – 15 °C
(if TOL < – 20 °C)
Pdh
kW
for air/water heat pumps: Tj
= – 15 °C
(if TOL < – 20 °C)
COPd
–
Bivalent temperature
T
biv
2
°C
for air/water heat pumps: tem-
perature operating limit
TOL
-20
°C
Central heating capacity cycle
intervals
Pcych
kW
Cycle intervals efficiency
COPcyc or
PERcyc
–
Degradation coefficient
Cdh
0.9
—
Water heating temperature
operating limit
WTOL
60
°C
Different mode of energy consumption from the active mode
Additional heating appliance
OFF mode
P
OFF
0.000
kW
Nominal heat output
Psup
0.00
kW
Thermostat mode off
P
TO
0.024
kW
Type of energy supply voltage
integration
Standby mode
P
SB
0.024
kW
Guard heating mode
P
CK
0.024
kW
Other items
Capacity control
Variable
For air/water heat pumps:
nominal air output to outside
—
2600
m
3
/h
Indoor/outdoor sound level
L
WA
x / 71
dB
For water or brine/water heat
pumps: nominal flow of brine or
water, outdoor heat exchanger
—
m
3
/h
Annual energy consumption
Q
HE
3.425
kWh or
GJ
For mixed central heating appliances with a heat pump
Stated load profile
Water central heating energy
efficiency
η
wh
%
Daily electrical power con-
sumption
Q
elec
kWh
Daily fuel consumption
Q
fuel
kWh
annual energy consumption
AEC
kWh
Annual fuel consumption
AFC
GJ