17
Technical features and dimensions
Model/s:
ARES PRO 348
Condensing Boilers:
YES
Low temperature boiler:
NO
Boiler type B1:
NO
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
NO
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
341
kW
Seasonal energy efficiency of central
heating
η
s
93
%
For central heating only and combination boilers: useful heat output
For central heating only and combination boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
341.4
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
88.4
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
113.2
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.7
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.270
kW
Heat loss in standby
P
stby
0.95
kW
At partial load
el
min
0.036
kW
Annual electrical consumption
Q
HE
1054
GJ
In standby mode
P
SB
0.005
kW
Emissions of nitrogen oxides ref. PCI (PCS)
NO
X
54 (49)
mg /
kWh
For mixed central heating appliances
Stated load profile
Domestic hot water production efficiency
η
WH
%
Daily electrical power consumption
Q
elec
kWh
Daily gas consumption
Q
fuel
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.
Model/s:
ARES PRO 400
Condensing Boilers:
YES
Low temperature boiler:
NO
Boiler type B1:
NO
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
NO
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
371
kW
Seasonal energy efficiency of central
heating
η
s
94
%
For central heating only and combination boilers: useful heat output
For central heating only and combination boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
373.0
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
88.4
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
124.0
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
98.0
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.425
kW
Heat loss in standby
P
stby
0.95
kW
At partial load
el
min
0.051
kW
Annual electrical consumption
Q
HE
1148
GJ
In standby mode
P
SB
0.005
kW
Emissions of nitrogen oxides ref. PCI (PCS)
NO
X
55 (50)
mg /
kWh
For mixed central heating appliances
Stated load profile
Domestic hot water production efficiency
η
WH
%
Daily electrical power consumption
Q
elec
kWh
Daily gas consumption
Q
fuel
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.
STD.005480/001
Summary of Contents for ARES PRO 150
Page 2: ...STD 005480 001 ...