29
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
- Then select the temperature for that time slot.
2-11
N.B.:
when selecting the temperature relating to
the time slot, one can also set the boiler in OFF
mode “
oFF
” that allows to switch the boiler
off in the pre-set time interval.
Repeat the operations for all the time slots and
for the days required.
To exit the time slot programming mode wait for
a few seconds or turn the selector until “
EsC
”
appears and press the main selector.
Time slot activation.
By pressing the button “
” one can activate system operation according
to the settings made previously. The activation
of the time slot mode is signalled by the activa-
tion of the relative symbol “ ”. To disable the
function and enable manual operation press the
button “ ” again.
2-12
Function lock.
In conjunction with the activa-
tion of the time slots, the manual room tem-
perature control mode is disabled; this status
is signalled by the activation of the relative
symbol “ ”.
Room temperature manual adjustment.
In
the event the time slots are not used, one can
set the room temperature simply by turning the
main selector.
2-13
Once the required room temperature is set, the
display will go back to showing the measured
room temperature.
Room humidity adjustment.
To display the
humidity in the room, press the main selector;
during the display of the humidity one can
change the desired humidity value, simply by
turning the main selector.
2-14
To go back to the display of the measured room
temperature, press the main selector again.
Domestic hot water temperature adjustment.
By pressing the button “ ” one can adjust the
temperature of the domestic hot water.
2-15
By turning the main selector one can select the
desired temperature. To exit the setting mode
simply press the button “ ”.
Anomalies display.
In the event there is an
anomaly in progress, the remote control displays
the status via the symbol “ ”.
2-16
The remote control stores the last 5 anomalies
indicating them with:
- A + number (e.g.
A 02
) for the anomalies
relating to the boiler.
- AH + number (e.g.
AH02
) for the anoma-
lies relating to the heat pump.
- AO + number (e.g.
A002
) for the anomalies
relating to the heat pump.
To display the anomalies in progress press and
hold the Mode “
” button and the time slot but-
ton “ ”; by turning the main selector clockwise
one can scroll the anomalies.
2-17
Directly from the remote zone control one can
reset the boiler anomalies, turn the selector
until “
res Alm
” appears and press the
main selector.
To exit the anomalies list wait for a few seconds
or turn the selector until “
EsC
” appears and
press the main selector.