31
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
DOMESTIC HOT WATER menu “
San
”
Menu item
Description
Adjustment
range
Default value
SSAN
DHW set
Domestic hot water temperature adjustment
25 ÷ 60 °C
45 °C
LEGi
Function
anti-legionella
Anti-legionella function activation
0 (disabled)
1 (enabled)
0
TiME
Function activation
time
anti-legionella
Anti-legionella function start time adjustment
00 - 23
00
Freq
Frequency
Anti-legionella function enabling frequency (1 = once a day, 2 = once every 2 days
up to the maximum value 7 = once every 7 days)
1 ÷ 7
1
OSAN
Domestic hot water
clock
It allows to set a specific operation period in domestic hot water comfort mode
(temperature set in the parameter “SSAN”), the same for all days of the week; out-
side this time period the system will maintain the domestic hot water at 25 °C
0 (disabled)
1 (enabled)
0
SoN1
Domestic hot water
Comfort 1 Off
Activation of first time slot with operation in domestic hot water Comfort mode
00 ÷ 23
00
SoF1
Domestic hot water
Comfort 1 Off
End of first time slot with operation in domestic hot water comfort mode
00 ÷ 23
00
SoN2
Domestic hot water
Comfort 2 Off
Activation of second time slot with operation in domestic hot water Comfort mode
00 ÷ 23
00
SoF2
Domestic hot water
Comfort 2 Off
End of second time slot with operation in domestic hot water comfort mode
00 ÷ 23
00
ESC
Output
By confirming the “ESC” item or pressing the button “ ” repeatedly one exits the
programming menu
Holiday Menu “
VACA
”
Menu item
Description
Adjustment
range
Default value
day
Days
Holiday days setting in which only the antifreeze function is enabled (00 function
disabled); each unit corresponds to 1 day
00 ÷ 365
00
Boiler anomalies menu “
Alrm
”
Menu item
Description
AlRM
Boiler anomalies
Display the last 5 boiler anomalies.
(the upper part displays the anomaly code, the lower part displays the sequence from 1 to 5).
Heat pump anomalies menu “
Alrh
”
Menu item
Description
AlRh
Heat pump anoma-
lies
Display the last 5 heat pump anomalies.
(the upper part displays the anomaly code, the lower part displays the sequence from 1 to 5).
Heat pump anomalies menu “
AlrO
”
Menu item
Description
AlRO
Heat pump anoma-
lies
Display the last 5 heat pump anomalies.
(the upper part displays the anomaly code, the lower part displays the sequence from 1 to 5).
INFO menu “
Info
”
VERS
Software version
Remote zone and boiler control software version
-
-
Summary of Contents for 3.025499