Page 50
Setup Manual
D.5
Testsuite
Picture 41: Testsuite screen
This function will be used for testing purposes.
Furthermore the screen shows some status information of the scanner.
Lamp on:
Switches the integrated lamps permanently on. While the lamps are
illuminated, the text on the button changes to
Lamp off
.
Push the button again to switch the lamps off.
EMV Test:
This button starts the EMV test function.
EMV test function means, that the scanner scans permanently without any
additional operator action.
Starting the EMV test:
Insert an appropriate document, for example the CSTT-1 test target which
comes with the scanner.
Push the
EMV Test
button.
The document will be transported through the scanner and scanned. After a
defined length the transport stops and the document will be transported in
reverse direction. This sequence will be repeated continuously.
Stopping the EMV test:
Push the
Home
button.
The test mode will be stopped and the touchscreen returns back to the
kiosk application.