Setup Manual
Page 131
E.6.1.1
White Balance
The white balance function is the most important function for consistent image quality.
During the white balance measurement, all light sources are combined and illuminate the
target. The measurement results in a correction function for the scan area.
Picture 118: White Reference Target on document table
Place the
White Reference Target
on the document table as shown in the picture above.
Click on Next Step to start the White Balance Adjustment sequence.
After the White Balance Adjustment has finished, the results will be displayed in a status
screen. A positive status is displayed in green. Any error will be shown in red, followed by
some explanatory remarks.
Note:
It is recommended to execute the White Balance Adjustment always after every
firmware update and after every cleaning, maintenance and repair of the
scanner.