10
Any adjustment, maintenance, etc. must be performed
by an authorized technician after disconnecting the
unit from the mains and from the gas supply.
INSTALLATION
GAS CONNECTION
This appliance shall be installed only by authorised persons and in accordance with the manufacturer's
installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations,
AS/NZS 5601 - Gas Installations and any other statutory regulations.
WARNING: THE APPLIANCE IS NOT SUITABLE FOR CONNECTION WITH A FLEXIBLE HOSE ASSEMBLY.
There are two ways to carry out the connection to the main gas line:
A.
The cooker can be connected with rigid pipe as specified in AS/NZS 5601.
B.
The cooker can be connected with an Australian approved Limited Flexibility Connector which complies
with AS 4631. The Limited Flexibility Connector used must be long enough to allow the appliance to be
pulled forward when service is required. Ensure the connnector is not be subjected to abrasion, crushing or
kinking during installation and that it is clear of the floor when the cooker is in the installed position. A
restraint device (typically chain) must be fitted by the installer. The device must restrict the appliance
movement to no more than 80% of the Limited Flexibility Connector length to prevent strain on the
gas connections when the cooker is pulled forward.
Anti-Tip Device
The cooker is factory fitted with two chains at the rear of the appliance (one on the left side and one on the
right
side) to prevent the appliance from tilting forward. The installer must connect the chains to the wall, directly
behind the chains as low as possible using a method that suits the wall material and restrains the weight of the
cooker. If the appliance is installed between two cupboards, the installer should drill a hole on each side of the
cupboards, pass the chains through the holes and anchor the chains within each cupboard.
Important: After fixing the chains ensure they are taut and test that the cooker does not tilt forward or sideways.
Before Leaving
Check all connections for gas leaks with soap and water. DO NOT use a naked flame for detecting leaks.
Ignite all burners both individually and concurrently to ensure correct operation of gas valves,
burners and ignition. Turn gas taps to low flame position and observe stability of the flame for each burner
individually and concurrently. When satisfied with the hotplate, please instruct the user on the correct method
of
operation. In case the appliance fails to operate correctly after all checks have been carried out, refer to the
authorised service provider in your area.
ADAPTING FOR OTHER GAS TYPES
The ovens are supplied to function as indicated on the plate. Should a change be necessary you should proceed
with the adaptation to another gas as described in the paragraph “Burner regulation”.
Data Label
The Data Label is located in the appliance door recess. This appliance is suitable for Natural Gas and
Universal LPG; ensure that the available gas supply matches the Data Label.