ADAPTING FOR DIFFERENT TYPES OF GAS
Replacing the injectors
IMPORTANT:
Before carrying out these oper ations you must disconnect appliance of electric power supply .
After adjustments, the seals must be replaced by the technician.
The air adjustment our burners is not necessary.
The burners can be adapted to different types of gas by mounting injectors suited to the user
’s gas (see NOZZLE
ADJUSTMENT TABLE). To do this you need:
1. Extract the pan stands, remove the head an cover of burners
2. With a 7 mm socket spanner unscrew and remove the nozzles from burners (see f g. 5)
3. Replace the burner injectors according to the gas to be used (see NOZZLE ADJUSTMENT TABLE)
4. Place the burners in the correct position
Fig. 5