- 29 -
S-2018
REV. D
CHANGING BATTERY PACK (P/N S-2003 and P/N S-2004)
1. Make sure the blower is turned off.
2. Open the battery pack compartment by pressing
on the latch connecting it to the blower.
3. Disconnect the connector parts and separate the battery
pack from the blower.
4. Connect the new battery pack.
5. Slot the connector into its designated place in the blower as
demonstrated.
6. Close the battery pack. Ensure that you do not pinch the
battery leads when closing the battery pack.
7. Ensure you hear an audible click when the battery pack
latch locks into place.
8. Operate normally.
Latch
Connector
Battery Pack
Battery Pack Seal
Summary of Contents for S-5000 Series