- 31 -
S-2018
REV. D
6.
Press the adapter plate assembly firmly to ensure the white
Velcro hook adheres to the inside wall of the blower. Then
gently pull the blue fabric strap to pull the plate assembly out of
the unit. The Velcro hook (color white) should remain adhered
to the inside of the blower. Verify that the Velcro loop strip
(black) is still firmly attached to the back of the adaptor plate.
7.
Set the Alkaline Battery Adaptor plate aside and use your thumbs
to apply pressure across the Velcro hook (white) inside the
blower to insure it is securely adhered.
8.
Install five Duracell D-Cell batteries into the Alkaline
Battery Adaptor. (NOTE: USE ONLY DURACELL D-
CELL ALKALINE BATTERIES!)
a.
Only remove and install the batteries when the
Alkaline Battery Adaptor Plate is removed from
the blower.
b.
Be sure to pay attention to the polarity (+ or -)
direction engraved into the back plate to insure
correct battery orientation. This is very important to
ensure the blower operates properly.
Velcro Loop on Back of
Adaptor Plate
Alkaline Pack
with Batteries
Installed
Summary of Contents for S-5000 Series