6.2 ALARM Indicator on the Control Panel Flashes ON and OFF
106
CCU-890 0804 VER2 (U) (E)
CCU Self Diagnostic Information
䂓
Self Diagnostic Information Screen
The following is the Self Diagnostic Information Screen of the CCU.
*** DIAGNOSTIC INFORMATION ***
Item Judgement Item Judgement
Head Power ON CCU Battery OK
Head Battery OK CCU Memory OK
Head Memory OK CCU Fan OK
Head Fan NOR
Head Temp OK Genlock INT
OPT Level L-H 10 Field Lock LOCK
CCU to Head ==> OK
Head to CCU ==> OK CCU to HEAD Comm OK
Cable Connection OK HEAD to CCU Comm OK
Safety Signal OK
Head ID OK
Power Tap 1---
DC Screen 16:9
UC Screen 16:9
Diagnosis result
Diagnosed item
䂓
List of Self Diagnostic Information
The CCU self diagnostic information may differ slightly for the standard specifi cation and the DUAL LINK (HS TYPE)
specifi cation. The following tables list the self diagnostic information for the standard specifi cation and the DUAL LINK (HS
TYPE) specifi cation respectively.
List of Self Diagnostic Information (Standard Specification)
Diagnosed Item
Description
Diagnosis
Result
Meaning
Camera
Head
Head Power
Power status of the camera head
ON
The camera head is powered ON.
OFF
The camera head is powered OFF.
Head Battery
Status of the battery in the MPU module of
the camera head
OK
Normal
NG
The backup battery voltage is low.
Head Memory
Status of the RAM IC memory in the MPU
module of the camera head
OK
Normal
NG
Data in the module is destroyed
Head Fan
Rotating status of fan of the camera head or
FA (Fiber Adaptor)
AUTO SSLOW Super-slow in auto mode
AUTO SLOW
Slow in auto mode
AUTO NOR
Normal in auto mode
AUTO FAST
Fast in auto mode
SSLOW
Super-slow in manual mode
SLOW
Slow in manual mode
NOR
Normal in manual mode
FAST
Fast in auto manual
Head Temp
Internal temperature of the camera head
OK
Normal
NG
The temperature is abnormally high or the
difference between the internal temperature and
outside-air temperature is at least 25°C.
Camera
Cable
(OPT Level L-H)
CCU to Head
Optical signal level sent from the CCU to the
camera head
(detected by the reception module in the
camera head)
OK
Good
ATTEN
The amount of light received decreased.
WARN
The amount of light received signifi cantly
decreased.
NG
Light cannot be received.
(OPT Level L-H)
Head to CCU
Optical signal level sent from the camera
head to the CCU
(detected by the reception module in the
CCU)
OK
Good
ATTEN
The amount of light received decreased.
WARN
The amount of light received signifi cantly
decreased.
NG
Light cannot be received.
Cable
Connection
Camera cable connection status between
the camera head and the CCU
OK
Normal
OPEN
Cable is not connected, or there is an open.
SHORT
A short circuit occurs in the cable.
Summary of Contents for CCU-890
Page 1: ...Products conforming to RoHS directive Camera Control Unit CCU 890 OPERATION MANUAL...
Page 2: ......
Page 15: ...1 OUTLINE OUTLINE...
Page 16: ...2 CCU 890 0804 VER2 U E...
Page 22: ......
Page 23: ...2 NAME and FUNCTION NAME and FUNCTION...
Page 24: ...10 CCU 890 0804 VER2 U E...
Page 37: ...3 FORMATS and GENLOCK FORMATS and GENLOCK...
Page 38: ...24 CCU 890 0804 VER2 U E...
Page 50: ...36 CCU 890 0804 VER2 U E...
Page 51: ...4 EQUIPMENT EQUIPMENT CONNECTIONS CONNECTIONS...
Page 52: ...38 CCU 890 0804 VER2 U E...
Page 78: ...64 CCU 890 0804 VER2 U E...
Page 79: ...5 CCU SETTINGS CCU SETTINGS and ADJUSTMENT and ADJUSTMENT...
Page 80: ...66 CCU 890 0804 VER2 U E...
Page 113: ...6 TROUBLE SHOOTING TROUBLE SHOOTING and MAINTENANCE and MAINTENANCE...
Page 114: ...100 CCU 890 0804 VER2 U E...
Page 126: ...112 CCU 890 0804 VER2 U E...
Page 128: ...114 CCU 890 0804 VER2 U E...
Page 130: ......
Page 131: ......