2. NAME AND FUNCTION OF EACH PART
2 - 3
BS-79 0212 VOL1 (U) (E)
BS-79
1 S1 switch
For factory setting. Do not change any switch position.
2 S2 switch
For factory setting. Do not change the position of any
switch other than switch 5.
Switch 5 is used to set the operating mode with more
than one control panel. For details, see Section 4.2.
3 S3 switch
For factory setting. Do not change any switch position.
4 S7 switch
For factory setting. Do not change any switch position.
5 GENLOCK indicator
On when the camera operates in the GENLOCK mode
(external synchronization).
6 HD H PHASE (COARSE) control
Adjusts the HDTV H phase (coarse adjustment).
Can be used only when the LOCAL/REM switch (12) is
in the "LOCAL" position.
7 HD H PHASE (FINE) control
Adjusts the HDTV H phase (fine adjustment).
Can be used only when the LOCAL/REM switch (12) is
in the "LOCAL" position.
8 SD H PHASE (COARSE) control
Adjusts the NTSC H phase (coarse adjustment).
Can be used only when the LOCAL/REM switch (12) is
in the "LOCAL" position.
9 SD H PHASE (FINE) control
Adjusts the NTSC H phase (fine adjustment).
Can be used only when the LOCAL/REM switch (12) is
in the "LOCAL" position.
10 SD SC PHASE (COARSE) control
Adjusts the NTSC SC phase (coarse adjustment).
Can be used only when the LOCAL/REM switch (12) is
in the "LOCAL" position.
11 SD SC PHASE (FINE) control
Adjusts the NTSC SC phase (fine adjustment).
Can be used only when the LOCAL/REM switch (12) is
in the "LOCAL" position.
12 LOCAL/REMOTE switch
Specifies whether to use the front controls of the PULSE
module ("LCL") or control panel ("REM") for adjusting
SC and H phases.
13 INCOM LEVEL (ENG) control
Controls the volume on the intercom receiver (ENG).
14 INCOM LEVEL (PROD) control
Controls the volume on the intercom receiver (PROD).
15 PRIVATE/COMMON switch
Changes the intercom conversation mode.
When this switch is in the "PRIV" position, conversation
only with the camera head is enabled.
When it is in the "COMM" position, conversation with
the camera head and system is enabled.
16 RCP ON/OFF switch
If you want to operate the BS using the control panel
connected to the OCP/CCP connector on the back panel,
position this switch to "OFF" or remove the RCP-50 from
the front panel of the BS.
If you want to operate the BS using the RCP-50 on the
front panel of the BS, set this switch to "ON".
17 RBK/RCP connector
Use this connector when mounting an RBK-79 or RCP-50
on the front panel of the BS.
18 DC output indicators
On when the voltage supplied to each BS module is
output normally.
19 SPARE FUSE holder
Holder for spare fuses
Two fuses are mounted at shipment.