Draco tera flex
Configuration via OSD
95
7.5
Extender Settings
The matrix automatically recognizes every extender module, physically connected to the matrix with a direct
cable connection, reads out its serial number and creates EXT Units automatically. This is the Flex Port
function of the matrix. Dual-Head extender modules will be recognized as two independent EXT Units.
Add-on modules are not created as independent EXT Units. The data of add-on modules is included in one
EXT Unit together with the associated extender module.
All EXT Units are managed in this menu. This includes the creation of new EXT Units and the deletion of
existing EXT Units.
NOTICE
The connection of a fixed port extender module (e.g., USB 2.0) to a Flex Port can cause unintended
results. EXT Units for USB 2.0 extender modules have to be created manually (see chapter 7.6,
page 96).
Fig. 75
OSD Menu Configuration - EXT Units
The following functions are available:
Button
Function
New
Create a new EXT Unit
Edit
Edit an existing EXT Unit
Delete
Delete an existing EXT Unit
Cancel
Reject changes
Okay
Apply changes