Configuration via OSD
Draco tera flex
74
7.3.4
Setting Switch Configuration
This menu enables shared operation of a CPU Device by two or more CON Devices. A CPU Device can be
controlled by only one CON Device at a time but can be taken over successively by other CON Devices.
Control of a CPU Unit by a CON Unit is relinquished after the expiration of an inactivity timer associated
with the controlling CON Device. The mouse or keyboard may also be used to take over control.
To allow a smooth and accurate function of the shared operation, you should use identical mice and
keyboards. They should be connected to the same USB-HID ports of each CON Unit.
The alternative is using the USB-HID Ghosting (see chapter 9.11, page 312).
When taking over control within 10 s, any assigned USB 2.0 extender modules if available, will not be
switched due to security and stability aspects.
The shared operation will be deactivated between CON Devices with a different priority as well as the
Release Time.
The switching parameters are set in this menu.
Fig. 66
OSD Menu Configuration - Switch
The following parameters can be configured:
Field
Entry
Description
Enable Video Sharing
Y
The user can switch to any CPU Device as an observer,
including ones that are already assigned to another user
(observer without keyboard/mouse access).
Note:
Switching with the
<Space>
key, not with the
<Enter>
key.
The operator only will be informed if further users connect as an
observer to the CPU Device that is connected to his CON
Device, if the option
Update Connection Info
is activated for
his CON EXT Unit.
N
Function not active (default)