Draco tera flex
Configuration via Management Software
183
Modifying Parameters
To modify parameters of an extender module, proceed as follows:
1. Select
Extender & Devices > EXT Units in the task area
.
2. Click the
Activate Edit Mode
menu item in the toolbar.
3. Select the EXT Units of the extender module whose parameters are to be displayed.
4. Click the
Parameter
tab on the right side of the working area.
5. Click the
Read
button in the symbol bar of the tab.
A query to read the parameters appears.
6. Click the
Yes
button to confirm the reading.
The parameters of the extender module are read out and displayed on the right side of the working
area. At the same time, the connection will be disconnected for a few seconds.
7. Modify the parameters.
8. Click the
Transmit
button.
A query for transmission appears.
9. Click the
Yes
button to transmit the modified parameters to the extender module.
The progress of the parameter transmission is displayed.
10. Click the
Close
button when the parameter transmission is completed (green).
Fig. 132
Management software menu Extender & Devices - EXT Units - Transmission finished
The parameter transmission is finished.
11. Click the
Deactivate Edit Mode
menu item in the toolbar.