![Ihse Draco tera flex Cat X 1G K480-C120 User Manual Download Page 189](http://html.mh-extra.com/html/ihse/draco-tera-flex-cat-x-1g-k480-c120/draco-tera-flex-cat-x-1g-k480-c120_user-manual_623701189.webp)
Draco tera flex
Configuration via Management Software
189
Button
Function
Transmit
Transmit the USB-HID Ghosting to the extender module and activate
Activate
Activate the USB-HID Ghosting
Deactivate
Deactivate the USB-HID Ghosting
Reset
Reset the USB-HID Ghosting of the extender module to factory settings
Assign
Assign the USB-HID Ghosting to several extender modules at the same time
During reading and writing USB-HID Ghosting information, there will be a short interrupt of the USB-HID
and video signal.
To read out and display the USB-HID Ghosting of CPU extender modules, proceed as follows:
1. Select
Extender & Devices > EXT Units
in the task area.
2. Click the
Activate Edit Mode
menu item in the toolbar.
3. Select the EXT Unit of the CPU extender module with active USB-HID Ghosting to be displayed.
4. Click the
USB-HID Ghosting
tab on the right side of the working area.
5. Click the
Read
button in the symbol bar of the tab.
A query to read the USB-HID Ghosting appears.
6. Click the
Yes
button to confirm the reading.
The current USB-HID Ghosting information of the CPU extender module is read out and displayed on
the right side of the working area. At the same time, the connection will be disconnected for a few
seconds.
To load a USB-HID Ghosting template (file extension
.dhg
) for a further distribution proceed as follows:
1. Select
Extender & Devices > EXT Units
in the task area.
2. Click the
Activate Edit Mode
menu item in the toolbar.
3. Select the EXT Unit of the CPU extender module to transmit the USB-HID Ghosting to.
4. Click the
USB-HID Ghosting
tab on the right side of the working area.
5. Click the
Open
button in the symbol bar of the tab.
6. Navigate to the respective template with the file extension
.dhg
and click the
Select
button.
7. Click the
Transmit
button in the symbol bar of the tab.
A query for transmission appears.
8. Click the
Yes
button to transmit the loaded USB-HID Ghosting to the CPU extender module.
The progress of the parameter transmission is displayed.
9. Click the
Close
button when the USB-HID Ghosting transmission is completed (green).